A meta-analysis of three decades of validating thoracic impedance cardiography.

E Raaijmakers1, T J Faes, R J Scholten, H G Goovaerts, R M Heethaar.   

Abstract

OBJECTIVE: To provide a meta-analysis of current literature concerning the validation of thoracic impedance cardiography (TIC) and to explain the variations in the reported results from the differences in the studies. DATA SOURCES: A computer-assisted search of English-language, German, and Dutch literature was performed for the period January 1966 to April 1997. Moreover, references from review articles were obtained. STUDY SELECTION: A total of 154 studies comparing measurements of cardiac output or related variables obtained from TIC and a reference method were analyzed. DATA EXTRACTION: Articles were classified by differences in TIC methodology, reference method, and subject characteristics. Fisher's Zf transformed correlation coefficients were used to compare results. Data were pooled using the random-effects method. DATA SYNTHESIS: An overall pooled r2 value of .67 (95% confidence interval, 0.64-0.71) was found. However, the correlation was higher in repeated-measurement designs than in single-measurement designs (r2 = .53; 95% confidence interval, 0.43-0.62). Further research using analysis of variance revealed a significant influence of the reference method and the subject characteristics on the correlation coefficient. The correlation was significantly better in animals than in cardiac patients. Subgroup analysis revealed that TIC correlated significantly better to the indirect Fick method than to echocardiography in healthy subjects. No significant influence of the applied TIC methodology was found. DISCUSSION: The overall r2 value of .67 indicates that TIC might be useful for trend analysis of different groups of patients. However, for diagnostic interpretation, a r2 value of .53 might not meet the required accuracy of the study. Great care should be taken when TIC is applied to the cardiac patient. However, because the applied reference method was of significant influence, differences between TIC and the reference method are incorrectly attributed to errors in TIC alone.

Entities:  

Mesh:

Year:  1999        PMID: 10397230     DOI: 10.1097/00003246-199906000-00053

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  33 in total

Review 1.  Cardiac output monitoring devices: an analytic review.

Authors:  Jahan Porhomayon; Ali El-Solh; Peter Papadakos; Nader Djalal Nader
Journal:  Intern Emerg Med       Date:  2011-12-07       Impact factor: 3.397

2.  Methods of monitoring shock.

Authors:  Ednan K Bajwa; Atul Malhotra; B Taylor Thompson
Journal:  Semin Respir Crit Care Med       Date:  2004-12       Impact factor: 3.119

3.  What initiates the pressor effect of salt in salt-sensitive humans? Observations in normotensive blacks.

Authors:  Olga Schmidlin; Alex Forman Anthony Sebastian; R Curtis Morris
Journal:  Hypertension       Date:  2007-03-19       Impact factor: 10.190

4.  Descending aortic flow contribution to intrathoracic impedance-development and preliminary testing of a dual impedance model.

Authors:  A Barry Baker; Chris N McLeod; Alastair J Roxburgh; Paul Bannister
Journal:  J Clin Monit Comput       Date:  2007-11-15       Impact factor: 2.502

Review 5.  The arterial Windkessel.

Authors:  Nico Westerhof; Jan-Willem Lankhaar; Berend E Westerhof
Journal:  Med Biol Eng Comput       Date:  2008-06-10       Impact factor: 2.602

6.  Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: comparison with thermodilution method.

Authors:  Arunodaya R Gujjar; K Muralidhar; Sanjay Banakal; Ratan Gupta; Talakad N Sathyaprabha; P S Jairaj
Journal:  J Clin Monit Comput       Date:  2008-04-17       Impact factor: 2.502

Review 7.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

8.  Influence of patent ductus arteriosus and ventilators on electrical velocimetry for measuring cardiac output in very-low/low birth weight infants.

Authors:  T Torigoe; S Sato; Y Nagayama; T Sato; H Yamazaki
Journal:  J Perinatol       Date:  2015-01-29       Impact factor: 2.521

Review 9.  Impedance cardiography: more questions than answers.

Authors:  David J Wang; Stephen S Gottlieb
Journal:  Curr Heart Fail Rep       Date:  2006-09

10.  Comparative effects of glyceryl trinitrate and amyl nitrite on pulse wave reflection and augmentation index.

Authors:  Lynn D Greig; Stephen J Leslie; Fraser W Gibb; Sherilyn Tan; David E Newby; David J Webb
Journal:  Br J Clin Pharmacol       Date:  2005-03       Impact factor: 4.335