Hepatic sonography: comparison of tissue harmonic and standard sonography techniques.

L E Hann1, A M Bach, L D Cramer, D Siegel, H H Yoo, R Garcia.   

Abstract

OBJECTIVE: This study was performed to compare tissue harmonic sonography of the liver with conventional sonography of the liver. SUBJECTS AND METHODS: Forty-eight patients underwent tissue harmonic and conventional sonography of the liver, using a randomized imaging sequence. Imaging parameters were standardized, but gain varied. Techniques were compared using predetermined impact analysis categories. If a finding was revealed by only one sonographic technique, additional confirmation was obtained by another imaging technique or by surgery. In a separate image quality analysis, masked images were reviewed by two experienced radiologists to evaluate fluid-solid differentiation, near-field, far-field, and overall image quality. Rankings were correlated with field of view of images and body habitus of patients as determined by body mass index.
RESULTS: Tissue harmonic sonography provided the same information as conventional sonography in 34 patients (71%) and added information in 14 patients (29%). The findings from tissue harmonic sonography resulted in altered treatment in five patients (10%). Eight patients (17%) had lesions revealed by tissue harmonic sonography only. Four patients (8%) had inadequate far-field visualization by both techniques. Both observers ranked tissue harmonic sonography the same as or better than standard sonography in 46 patients (96%) for fluid-solid differentiation, in 46 patients (96%) for near-field image quality, and in 45 patients (94%) for overall image quality. For far-field image quality, one observer ranked tissue harmonic sonography the same as or better than conventional sonography in 40 patients (83%), and the second observer, in 41 patients (85%). Image quality ratings showed no correlation with body habitus of the patients or field of view of images.
CONCLUSION: Tissue harmonic sonography of the liver provides more information and better image quality than does conventional sonography of the liver.

Entities:  

Mesh:

Year:  1999        PMID: 10397127     DOI: 10.2214/ajr.173.1.10397127

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  13 in total

1.  Phase-inversion tissue harmonic imaging compared to fundamental B-mode ultrasound in the evaluation of the pathology of large and small bowel.

Authors:  T Schmidt; C Hohl; P Haage; D Honnef; A H Mahnken; G Krombach; W Piroth; R W Günther
Journal:  Eur Radiol       Date:  2005-04-08       Impact factor: 5.315

2.  [Modern ultrasound technologies and their application in pediatric urinary tract imaging].

Authors:  K Darge; A Heidemeier
Journal:  Radiologe       Date:  2005-12       Impact factor: 0.635

Review 3.  Recent applications of ultrasound: diagnosis and treatment of hepatocellular carcinoma.

Authors:  Hitoshi Maruyama; Masaaki Ebara
Journal:  Int J Clin Oncol       Date:  2006-08       Impact factor: 3.402

Review 4.  Current role of ultrasound for the management of hepatocellular carcinoma.

Authors:  Hitoshi Maruyama; Masaharu Yoshikawa; Osamu Yokosuka
Journal:  World J Gastroenterol       Date:  2008-03-21       Impact factor: 5.742

5.  Focal hepatic lesions characterisation by different sonographic techniques: a prospective analysis.

Authors:  Upasana Ranga; Naveen Kalra; Akshay K Saxena; Anmol Bhatia; Manavjit S Sandhu; Ajay K Duseja; Yogesh K Chawla; Niranjan Khandelwal
Journal:  J Ultrasound       Date:  2015-06-23

6.  Phase-inversion tissue harmonic imaging compared with conventional B-mode ultrasound in the evaluation of pancreatic lesions.

Authors:  Christian Hohl; Thorsten Schmidt; Patrick Haage; Dagmar Honnef; Marcus Blaum; Gundula Staatz; Rolf W Guenther
Journal:  Eur Radiol       Date:  2004-01-09       Impact factor: 5.315

7.  Ultrasound evaluation of normal and abnormal fetuses: comparison of conventional, tissue harmonic, and pulse-inversion harmonic imaging techniques.

Authors:  Jeong-Ah Ryu; Bohyun Kim; Sooah Kim; Soon Ha Yang; Moon Hae Choi; Hyeong Sik Ahn
Journal:  Korean J Radiol       Date:  2003 Jul-Sep       Impact factor: 3.500

8.  Fatty liver disease in severe obese patients: diagnostic value of abdominal ultrasound.

Authors:  Alessandro de Moura Almeida; Helma Pinchemel Cotrim; Daniel Batista Valente Barbosa; Luciana Gordilho Matteoni de Athayde; Adimeia Souza Santos; Almir Galvão Vieira Bitencourt; Luiz Antonio Rodrigues de Freitas; Adriano Rios; Erivaldo Alves
Journal:  World J Gastroenterol       Date:  2008-03-07       Impact factor: 5.742

9.  Comparison of fundamental sonography, tissue-harmonic sonography, fundamental compound sonography, and tissue-harmonic compound sonography for focal hepatic lesions.

Authors:  Se Hyung Kim; Jeong Min Lee; Kwang Gi Kim; Jong Hyo Kim; Joon Koo Han; Jae Young Lee; Byung Ihn Choi
Journal:  Eur Radiol       Date:  2006-03-29       Impact factor: 7.034

10.  Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours.

Authors:  D- A Clevert; E M Jung; K-P Jungius; K Ertan; R Kubale
Journal:  Eur Radiol       Date:  2006-07-06       Impact factor: 5.315

View more