An implantable impedance pneumograph monitor for detection of diaphragm contraction and airway obstruction during diaphragm pacing.

B D Schmit1, H Kayyali, B Makovos, J T Mortimer.   

Abstract

Impedance pneumography signals were characterised during diaphragm pacing using stimulating and recording electrodes placed on the abdominal surface of the diaphragm. These measurements were useful for the detection of muscle contraction without confounding effects from stimulus artifacts. Impedance pneumography signals were measured using 23 epimysial electrodes implanted in seven dogs with 1-5 experiments on each electrode. The polarity of the change in impedance associated with diaphragm pacing differed for each recording electrode and its configuration. Thirty-four of 57 cases produced increased impedance, 11 produced decreased impedance and the remaining 12 depended on the level of diaphragm activation. Impedance pneumography signals were useful for detecting complete airway obstruction. The mean difference between the impedance measured during open and obstructed airway conditions was 80% of the open airway impedance signal. The difference between open and obstructed airway impedance measurements was a mean of 2.3 times larger with a recording electrode on the same hemidiaphragm as the stimulating electrode, compared to an electrode placed on the opposite hemidiaphragm (p < 0.05, paired t test, four dogs). In addition, the differences between open and completely obstructed airways were a mean of 2.8 times larger when the second recording electrode was placed on the thorax at the fifth intercostal space, compared to the ninth intercostal space (p < 0.05, two-factor ANOVA, one dog, two replicates). It was concluded that impedance pneumograph circuitry could be incorporated into an existing diaphragm pacer using electrodes placed on the diaphragm to provide valuable measurements of the function of the device.

Entities:  

Mesh:

Year:  1999        PMID: 10396819     DOI: 10.1007/bf02513283

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  16 in total

1.  QUANTITATIVE EVALUATION OF IMPEDANCE SPIROMETRY IN MAN.

Authors:  L E BAKER; L A GEDDES; H E HOFF
Journal:  Am J Med Electron       Date:  1965 Apr-Jun

2.  Laparoscopic placement of electrodes for diaphragm pacing using stimulation to locate the phrenic nerve motor points.

Authors:  B D Schmit; T A Stellato; M E Miller; J T Mortimer
Journal:  IEEE Trans Rehabil Eng       Date:  1998-12

3.  Staple penetration and staple histological response for attaching an epimysial electrode onto the abdominal surface of the diaphragm using a laparoscopic approach.

Authors:  B D Schmit; T A Stellato; J T Mortimer
Journal:  Surg Endosc       Date:  1997-01       Impact factor: 4.584

4.  The tissue response to epimysial electrodes for diaphragm pacing in dogs.

Authors:  B D Schmit; J T Mortimer
Journal:  IEEE Trans Biomed Eng       Date:  1997-10       Impact factor: 4.538

5.  Factors in impedance pneumography.

Authors:  A M Albisser; A B Carmichael
Journal:  Med Biol Eng       Date:  1974-09

6.  Central hypoventilation; long-term ventilatory assistance by radiofrequency electrophrenic respiration.

Authors:  W W Glenn; W G Holcomb; J B Gee; R Rath
Journal:  Ann Surg       Date:  1970-10       Impact factor: 12.969

7.  Physiological factors underlying transthoracic impedance variations in respiration.

Authors:  L E Baker; L A Geddes; H E Hoff; C J Chaput
Journal:  J Appl Physiol       Date:  1966-09       Impact factor: 3.531

8.  Intramuscular electrical activation of the phrenic nerve.

Authors:  D K Peterson; M Nochomovitz; A F DiMarco; J T Mortimer
Journal:  IEEE Trans Biomed Eng       Date:  1986-03       Impact factor: 4.538

Review 9.  Diaphragm pacing by electrical stimulation of the phrenic nerve.

Authors:  W W Glenn; M L Phelps
Journal:  Neurosurgery       Date:  1985-12       Impact factor: 4.654

10.  Ventilatory support by pacing of the conditioned diaphragm in quadriplegia.

Authors:  W W Glenn; J F Hogan; J S Loke; T E Ciesielski; M L Phelps; R Rowedder
Journal:  N Engl J Med       Date:  1984-05-03       Impact factor: 91.245

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.