Development of an automated measurement system using a diffusion scrubber and high-performance liquid chromatography for the monitoring of formaldehyde and acetaldehyde in automotive exhaust gas.

Y Komazaki1, Y Narita, S Tanaka.   

Abstract

An automated measurement system for monitoring formaldehyde (HCHO) and acetaldehyde (CH3CHO) in automotive exhaust gas by using a diffusion scrubber in combination with high-performance liquid chromatography (HPLC) was developed. HCHO and CH3CHO are effectively collected by the diffusion scrubber, which consists of a hydrophobic porous PTFE tube disposed concentrically within a Pyrex-glass tube and a scrubbing solution. 2,4-Dinitrophenylhydrazine is used as the scrubbing solution for trapping HCHO and CH3CHO, which are derivatized to formaldehyde 2,4-dinitrophenylhydrazone (DNPH-HCHO) and acetaldehyde 2,4-dinitrophenylhydrazone (DNPH-CH3CHO), respectively, with phosphoric acid as an acid catalyst. After the collection of the gas sample, the sample solution in the diffusion scrubber is injected into the HPLC system and DNPH-HCHO and DNPH-CH3CHO are separated and determined. All measurement operations are sequenced by a programmable controller and an automated continuous measurement can be performed at 10 min intervals. The collection efficiencies of HCHO and CH3CHO were higher than 97% at a gas flow rate of 0.21 min-1. The detection limit (3 sigma of the blank value) was 0.001 ppm v/v for HCHO and CH3CHO for a 1.61 gas sample volume. No interference of co-existing nitrogen dioxide (NO2) in the collection of HCHO and CH3CHO was observed. The average concentration of HCHO in the exhaust gas from methanol-fueled vehicles was 77.3 ppm v/v (n = 5) in the cold-phase mode when engines were first started. In the hot-phase mode, the average concentration of HCHO was 3.3 ppm v/v (n = 15). The concentrations of HCHO measured by this automated measurement system were in good agreement with those obtained using the impinger-HPLC method.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10396812     DOI: 10.1039/a805999c

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  2 in total

1.  Rational Design of SnO2 Hollow Microspheres Functionalized with Derivatives of Pt Loaded MOFs for Superior Formaldehyde Detection.

Authors:  Lanlan Guo; Yuanyuan Wang; Hua Zeng; Yanji Feng; Xueli Yang; Saisai Zhang; Yonghao Xu; Guodong Wang; Yan Wang; Zhanying Zhang
Journal:  Nanomaterials (Basel)       Date:  2022-05-31       Impact factor: 5.719

2.  Acute oral ethanol exposure triggers asthma in cockroach allergen-sensitized mice.

Authors:  Jacqueline C Bouchard; Jiyoun Kim; Dominic R Beal; Louis J Vaickus; Florin L Craciun; Daniel G Remick
Journal:  Am J Pathol       Date:  2012-07-13       Impact factor: 4.307

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.