Literature DB >> 10396626

A neural interface for a cortical vision prosthesis.

R A Normann1, E M Maynard, P J Rousche, D J Warren.   

Abstract

The development of a cortically based vision prosthesis has been hampered by a lack of basic experiments on phosphene psychophysics. This basic research has been hampered by the lack of a means to safely stimulate large numbers of cortical neurons. Recently, a number of laboratories have developed arrays of silicon microelectrodes that could enable such basic studies on phosphene psychophysics. This paper describes one such array, the Utah electrode array, and summarizes neurosurgical, physiological and histological experiments that suggest that such an array could be implanted safely in visual cortex. We also summarize a series of chronic behavioral experiments that show that modest levels of electrical currents passed into cortex via this array can evoke sensory percepts. Pending the successful outcome of biocompatibility studies using such arrays, high count arrays of penetrating microelectrodes similar to this design could provide a useful tool for studies of the psychophysics of phosphene perception in human volunteers. Such studies could provide a proof-of-concept for cortically based artificial vision.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10396626     DOI: 10.1016/s0042-6989(99)00040-1

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  63 in total

1.  Scalp VEPs and intra-cortical responses to chromatic and achromatic stimuli in primates.

Authors:  J J Kulikowski; A G Robson; I J Murray
Journal:  Doc Ophthalmol       Date:  2002-09       Impact factor: 2.379

2.  Towards the cortical representation of form and motion stimuli generated by a retina implant.

Authors:  Thomas Schanze; Nina Greve; Lutz Hesse
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-07-29       Impact factor: 3.117

Review 3.  Retinal replacement--the development of microelectronic retinal prostheses--experience with subretinal implants and new aspects.

Authors:  Helmut G Sachs; Veit-Peter Gabel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-08-10       Impact factor: 3.117

4.  Intrinsic dendritic filtering gives low-pass power spectra of local field potentials.

Authors:  Henrik Lindén; Klas H Pettersen; Gaute T Einevoll
Journal:  J Comput Neurosci       Date:  2010-05-26       Impact factor: 1.621

Review 5.  [Status of the subretinal implant project. An overview].

Authors:  F Gekeler; E Zrenner
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

6.  [Epiretinal visual prostheses].

Authors:  P Walter; W Mokwa
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

7.  Demonstration of artificial visual percepts generated through thalamic microstimulation.

Authors:  John S Pezaris; R Clay Reid
Journal:  Proc Natl Acad Sci U S A       Date:  2007-04-23       Impact factor: 11.205

8.  Generation of synthetic spike trains with defined pairwise correlations.

Authors:  Ernst Niebur
Journal:  Neural Comput       Date:  2007-07       Impact factor: 2.026

9.  Finite element analysis of a floating microstimulator.

Authors:  Mesut Sahin; Syed S Ur-Rahman
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2007-06       Impact factor: 3.802

10.  Subretinal implantation and testing of polyimide film electrodes in cats.

Authors:  Helmut G Sachs; Thomas Schanze; Marcus Wilms; Andreas Rentzos; Ursula Brunner; Florian Gekeler; Lutz Hesse
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-12-01       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.