Literature DB >> 10393585

Comparison of the debonding characteristics of two innovative ceramic bracket designs.

S E Bishara1, M E Olsen, L VonWald, J R Jakobsen.   

Abstract

Two new ceramic brackets-one designed with a metal-lined arch wire slot and the other with an epoxy resin base-have been recently introduced. The new brackets are thought to combine the esthetic advantages of ceramics and the functional advantages of debonding metal brackets. The purpose of this study was to compare the following: 1) the shear bond strength of the 2 brackets, and 2) the bond failure location when the brackets are debonded with pliers. Sixty-one Clarity (3M Unitek) collapsible ceramic brackets and 66 MXi (TP Orthodontics, Inc) brackets were bonded to the teeth with the same bonding system. The Zwick Universal Test Machine (Zwick Gm bH & Co) was used to determine the shear bond strength force levels needed to debond the brackets. The appropriate pliers also were used to debond both types of brackets to determine the mode of bond failure that will be encountered clinically. After debonding, all the teeth and brackets were examined with 10x magnification. Any adhesive that remained after the bracket removal was assessed according to the Adhesive Remnant Index. The findings indicated that the shear bond strength of the Clarity ceramic brackets was significantly greater than that of the MXi ceramic brackets. However, both brackets exhibited forces that were adequate for clinical use. The Adhesive Remnant Index scores for both the shear test and the plier debonding indicated a similar bond failure pattern when the 2 ceramic brackets were compared with each other. This suggests that, when these brackets are debonded with the Weingart (Ormco) and ETM (Ormco) pliers, there was a greater tendency for most of the adhesive to remain on the enamel surface. In conclusion, the most efficient method to debond the MXi ceramic bracket is by placing the blades of the ETM 346 pliers between the bracket base and the enamel surface. On the other hand, the most efficient method of debonding the Clarity bracket is by using the Weingart pliers and applying pressure to the tiewings. When the 2 ceramic brackets were debonded as recommended here, most of the residual adhesive remained on the enamel surface, a pattern similar to the one observed previously with metal brackets. The failure at the bracket-adhesive interface decreases the probability of enamel damage but necessitates the removal of more residual adhesive after debonding.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10393585     DOI: 10.1016/s0889-5406(99)70307-0

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  6 in total

1.  Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study.

Authors:  Behnam Mirzakouchaki; Sajjad Shirazi; Reza Sharghi; Samaneh Shirazi; Mahsan Moghimi; Shirin Shahrbaf
Journal:  J Clin Exp Dent       Date:  2016-02-01

2.  Fluoride influences nickel-titanium orthodontic wires' surface texture and friction resistance.

Authors:  Mona Aly Abbassy
Journal:  J Orthod Sci       Date:  2016 Oct-Dec

3.  Shear Bond Strength of Orthodontic Brackets Bonded to Zirconium Crowns.

Authors:  Blerim Mehmeti; Bleron Azizi; Jeta Kelmendi; Donika Iljazi-Shahiqi; Željko Alar; Sandra Anić-Milošević
Journal:  Acta Stomatol Croat       Date:  2017-06

4.  Comparison of Shear Bond Strength Orthodontic Brackets Bonded to Zirconia and Lithium Disilicate Crowns.

Authors:  Blerim Mehmeti; Jeta Kelmendi; Donika Iiljazi-Shahiqi; Bleron Azizi; Suzana Jakovljevic; Fehim Haliti; Sandra Anić-Milošević
Journal:  Acta Stomatol Croat       Date:  2019-03

5.  Effect of the different debonding strength of metal and ceramic brackets on the degree of enamel microcrack healing.

Authors:  Piyaphong Nimplod; Ratchawan Tansalarak; Tanapon Sornsuwan
Journal:  Dental Press J Orthod       Date:  2021-06-25

6.  Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study.

Authors:  Álvaro Zubizarreta-Macho; Martina Triduo; Jorge Alonso Pérez-Barquero; Clara Guinot Barona; Alberto Albaladejo Martínez
Journal:  J Clin Med       Date:  2020-04-12       Impact factor: 4.241

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.