Literature DB >> 10393056

Visual function correlates with nerve fiber layer thickness in eyes affected by ocular hypertension.

V Parisi1, G Manni, S A Gandolfi, M Centofanti, G Colacino, M G Bucci.   

Abstract

PURPOSE: To test whether the high variability observed when measuring pattern electroretinogram (PERG), visual evoked potentials (VEP), and spatial contrast sensitivity (SCS) in eyes with ocular hypertension is associated with variation in nerve fiber layer thickness, as measured by optical coherence tomography (OCT).
METHODS: The study involved 32 untreated eyes (32 patients; age range, 29-64 years) showing a normal whiteon-white 24/2 Humphrey (San Leandro, CA) perimetry, IOP between 23 and 28 mm Hg, best corrected acuity of 20/20 or better, and none of the following papillary signs on conventional color stereo slides: rim notch(es), peripapillary splinter hemorrhages, or increased vertical-to-horizontal cup-to-disc ratio. On recruitment, each eye underwent SCS testing, OCT, PERG, and VEP recordings. Linear regression (Pearson's test) or Spearman's rank regression was adopted for the analysis of the data.
RESULTS: The 95% confidence limits of the electrophysiological data were: PERG P50 latency, 59.3 to 63 msec; PERG P50 to N95 amplitude, 0.74 to 1.15 cmV; VEP P100 latency, 113 to 118 msec; VEP N75 to P100 amplitude, 3.81 to 4.90 micromV. The 360 degrees nerve fiber layer thickness overall (NFLO) ranged between 113 and 169 microm (145+/-16 microm; mean+/-SD) and significantly correlated with PERG P50 to N95 amplitude (r: 0.518; P = 0.002), PERG P50 latency (r: -0.470; P = 0.007), VEP N75 to P100 amplitude (r: 0.460; P = 0.008), VEP P100 latency (r = -0.422; P = 0.016) and SCS at 3 cyc/deg (r: -0.358; P = 0.044).
CONCLUSIONS: The variability of PERG, VEP, and SCS testing observed in eyes with ocular hypertension is associated with differences in NFL thickness (the thinner the layer, the worse the visual function).

Entities:  

Mesh:

Year:  1999        PMID: 10393056

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  13 in total

1.  The Humphrey optical coherence tomography scanner: quantitative analysis and reproducibility study of the normal human retinal nerve fibre layer.

Authors:  A L Jones; N J Sheen; R V North; J E Morgan
Journal:  Br J Ophthalmol       Date:  2001-06       Impact factor: 4.638

2.  Normative data for a user-friendly paradigm for pattern electroretinogram recording.

Authors:  Vittorio Porciatti; Lori M Ventura
Journal:  Ophthalmology       Date:  2004-01       Impact factor: 12.079

3.  Pattern electroretinogram association with spectral domain-OCT structural measurements in glaucoma.

Authors:  C Bowd; A Tafreshi; L M Zangwill; F A Medeiros; P A Sample; R N Weinreb
Journal:  Eye (Lond)       Date:  2010-12-24       Impact factor: 3.775

4.  Pattern electroretinogram optimized for glaucoma screening (PERGLA) and retinal nerve fiber thickness in suspected glaucoma and ocular hypertension.

Authors:  Raimondo Forte; Lucia Ambrosio; Paola Bonavolontà; Gennaro Ambrosio
Journal:  Doc Ophthalmol       Date:  2009-12-25       Impact factor: 2.379

5.  The relationship between retinal ganglion cell function and retinal nerve fiber thickness in early glaucoma.

Authors:  Lori M Ventura; Nancy Sorokac; Roosevelt De Los Santos; William J Feuer; Vittorio Porciatti
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-09       Impact factor: 4.799

6.  Pattern electroretinogram abnormality and glaucoma.

Authors:  Lori M Ventura; Vittorio Porciatti; Kyoko Ishida; William J Feuer; Richard K Parrish
Journal:  Ophthalmology       Date:  2005-01       Impact factor: 12.079

7.  Structure-function relationship in ocular hypertension and glaucoma: interindividual and interocular analysis by OCT and pattern ERG.

Authors:  Benedetto Falsini; Dario Marangoni; Tommaso Salgarello; Giovanna Stifano; Lucrezia Montrone; Francesca Campagna; Stefania Aliberti; Emilio Balestrazzi; Alberto Colotto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-04-02       Impact factor: 3.117

8.  Retinal nerve fiber layer thickness in recovered and persistent amblyopia.

Authors:  Atsushi Miki; Motohiro Shirakashi; Kiyoshi Yaoeda; Yu Kabasawa; Satoshi Ueki; Mineo Takagi; Haruki Abe
Journal:  Clin Ophthalmol       Date:  2010-09-20

9.  Pattern ERG and RNFL thickness in hypertensive eyes with normal blue-yellow visual field.

Authors:  Maurizio G Uva; Massimo Di Pietro; Antonio Longo; Katia Lauretta; Michele Reibaldi; Alfredo Reibaldi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-08-12       Impact factor: 3.117

10.  Optical Coherence Tomography in Alzheimer's Disease: A Meta-Analysis.

Authors:  Gianluca Coppola; Antonio Di Renzo; Lucia Ziccardi; Francesco Martelli; Antonello Fadda; Gianluca Manni; Piero Barboni; Francesco Pierelli; Alfredo A Sadun; Vincenzo Parisi
Journal:  PLoS One       Date:  2015-08-07       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.