Literature DB >> 10393035

Excimer laser effects on outflow facility and outflow pathway morphology.

J S Schuman1, W Chang, N Wang, A W de Kater, R R Allingham.   

Abstract

PURPOSE: To determine the relative contributions to aqueous outflow resistance of the tissues distal to the inner wall of Schlemm's canal.
METHODS: While performing constant pressure perfusion at 10 mm Hg, a 193-nm excimer laser (Questek) was used to precisely remove portions of sclera, unroofing Schlemm's canal while leaving the inner wall intact. The laser beam was masked to produce a beam 2 mm by 1 mm. The laser output was constant at a fluency of 75 mJ/cm2 and 20 Hz. The excimer laser at a frequency of 1 Hz was used as the aiming beam. Photoablation was performed on human cadaver eyes at the limbus at an angle of 0 degrees to 45 degrees from the optical axis. As the excimer photoablations progressed, Schlemm's canal was visualized by the fluorescence of the Barany's solution containing fluorescein dye. After perfusion fixation the eyes were immersion-fixed overnight. The facility of outflow before (Co) and after (Ce) the excimer ablation was measured in 7 eyes.
RESULTS: The facility of outflow increased in all eyes after the excimer sinusotomy, from a mean of 0.29+/-0.02 before the sinusotomy to 0.37+/-0.03 microl/min per mm Hg after (P < 0.05). The mean ratio of outflow facility after and before ablation (Ce/Co) was 1.27+/-0.08 (range, 1.20-1.39), a reduction of outflow resistance of 21.3%. Using the formula of Ellingsen and Grant (1972), percentage of resistance to outflow eliminated = 100 [1 - alphaCo/Ce - (1 - alpha)Co], where alpha = fraction of the circumference dissected. Assuming that because of circumferential flow approximately 50% of Schlemm's canal is drained by the single opening made in the outer wall ablation studies, this results in resistance to outflow eliminated of 35%, which is consistent with the calculated eliminated resistance derived from the data of Rosenquist et al., 1989. Light and scanning electron microscopy confirmed the integrity of the inner wall Schlemm's canal underlying the area of ablation.
CONCLUSIONS: The results provide direct evidence indicating that approximately one third of resistance to outflow in the human eye lies distal to the inner wall Schlemm's canal in an enucleated perfused human eye.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10393035

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  23 in total

1.  Trabecular meshwork bypass tube shunt: initial case series.

Authors:  D Spiegel; K Kobuch
Journal:  Br J Ophthalmol       Date:  2002-11       Impact factor: 4.638

2.  A novel technique of ab interno glaucoma surgery: follow-up results after 24 months.

Authors:  Bojan Pajic; Grigoris Pallas; Heinrich Gerding; Gerding Heinrich; Matthias Böhnke
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-07-19       Impact factor: 3.117

3.  Detailed visualization of the anterior segment using fourier-domain optical coherence tomography.

Authors:  Sanjay Asrani; Marinko Sarunic; Cecilia Santiago; Joseph Izatt
Journal:  Arch Ophthalmol       Date:  2008-06

Review 4.  Precision medicine to prevent glaucoma-related blindness.

Authors:  Sayoko E Moroi; David M Reed; David S Sanders; Ahmed Almazroa; Lawrence Kagemann; Neil Shah; Nakul Shekhawat; Julia E Richards
Journal:  Curr Opin Ophthalmol       Date:  2019-05       Impact factor: 3.761

Review 5.  A single gene connects stiffness in glaucoma and the vascular system.

Authors:  Teresa Borrás
Journal:  Exp Eye Res       Date:  2016-09-01       Impact factor: 3.467

Review 6.  Toward in vivo two-photon analysis of mouse aqueous outflow structure and function.

Authors:  Jose M Gonzalez; Minhee K Ko; Andrius Masedunskas; Young-Kwon Hong; Roberto Weigert; James C H Tan
Journal:  Exp Eye Res       Date:  2016-05-12       Impact factor: 3.467

Review 7.  Aqueous outflow - A continuum from trabecular meshwork to episcleral veins.

Authors:  Teresia Carreon; Elizabeth van der Merwe; Ronald L Fellman; Murray Johnstone; Sanjoy K Bhattacharya
Journal:  Prog Retin Eye Res       Date:  2016-12-24       Impact factor: 21.198

Review 8.  Gene transfer to the outflow tract.

Authors:  Yalong Dang; Ralitsa Loewen; Hardik A Parikh; Pritha Roy; Nils A Loewen
Journal:  Exp Eye Res       Date:  2016-04-27       Impact factor: 3.467

9.  Variations in active outflow along the trabecular outflow pathway.

Authors:  Elliott D K Cha; Jia Xu; Lihua Gong; Haiyan Gong
Journal:  Exp Eye Res       Date:  2016-01-13       Impact factor: 3.467

10.  Estimating outflow facility through pressure dependent pathways of the human eye.

Authors:  David W Smith; Bruce S Gardiner
Journal:  PLoS One       Date:  2017-12-20       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.