Literature DB >> 10391581

A biomimetic controller for a multifinger prosthesis.

R L Abboudi1, C A Glass, N A Newby, J A Flint, W Craelius.   

Abstract

A novel controller for a multifinger hand prosthesis was developed and tested to measure its accuracy and performance in transducing volitional signals for individual "phantom" fingers. Pneumatic sensors were fabricated from open-cell polymeric foam, and were interposed between the prosthetic socket and superficial extrinsic tendons associated with individual finger flexion. Test subjects were prompted to move individual fingers or combinations thereof to execute either taps or grasps. Sensor outputs were processed by a computer that controlled motions of individual fingers on a mechanical prosthesis. Trials on three upper-limb amputees showed that after brief training sessions, the TAP controller was effective at producing voluntary flexions of individual fingers and grasping motions. Signal energies were between 5 and 25 dB relative to noise from all sources, including adjacent sensors, indicating high degrees of both sensitivity and specificity for tendon-associated transduction. Finger flexions at up to three repetitions per second, and rhythmic tapping of sequential fingers were readily transduced. One amputee subject was able to play a short piano piece with three fingers, at approximately one-quarter normal tempo. TAP sensors responded linearly to graded forces from individual fingers, indicating proportional force control. Our results demonstrate the feasibility of restoring some degree of finger dexterity by noninvasive sensing of extrinsic tendons.

Entities:  

Mesh:

Year:  1999        PMID: 10391581     DOI: 10.1109/86.769401

Source DB:  PubMed          Journal:  IEEE Trans Rehabil Eng        ISSN: 1063-6528


  11 in total

1.  Modeling and preliminary testing socket-residual limb interface stiffness of above-elbow prostheses.

Authors:  Jonathon W Sensinger; Richard F ff Weir
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-04       Impact factor: 3.802

2.  Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions.

Authors:  John-John Cabibihan; Raditya Pradipta; Shuzhi Sam Ge
Journal:  J Neuroeng Rehabil       Date:  2011-03-30       Impact factor: 4.262

Review 3.  Non-invasive control interfaces for intention detection in active movement-assistive devices.

Authors:  Joan Lobo-Prat; Peter N Kooren; Arno H A Stienen; Just L Herder; Bart F J M Koopman; Peter H Veltink
Journal:  J Neuroeng Rehabil       Date:  2014-12-17       Impact factor: 4.262

4.  Surveying the interest of individuals with upper limb loss in novel prosthetic control techniques.

Authors:  Susannah M Engdahl; Breanne P Christie; Brian Kelly; Alicia Davis; Cynthia A Chestek; Deanna H Gates
Journal:  J Neuroeng Rehabil       Date:  2015-06-13       Impact factor: 4.262

Review 5.  A Review of Force Myography Research and Development.

Authors:  Zhen Gang Xiao; Carlo Menon
Journal:  Sensors (Basel)       Date:  2019-10-20       Impact factor: 3.576

6.  The effects of robotic assistance on upper limb spatial muscle synergies in healthy people during planar upper-limb training.

Authors:  Adriana Cancrini; Paolo Baitelli; Matteo Lavit Nicora; Matteo Malosio; Alessandra Pedrocchi; Alessandro Scano
Journal:  PLoS One       Date:  2022-08-08       Impact factor: 3.752

Review 7.  Proceedings of the first workshop on Peripheral Machine Interfaces: going beyond traditional surface electromyography.

Authors:  Claudio Castellini; Panagiotis Artemiadis; Michael Wininger; Arash Ajoudani; Merkur Alimusaj; Antonio Bicchi; Barbara Caputo; William Craelius; Strahinja Dosen; Kevin Englehart; Dario Farina; Arjan Gijsberts; Sasha B Godfrey; Levi Hargrove; Mark Ison; Todd Kuiken; Marko Marković; Patrick M Pilarski; Rüdiger Rupp; Erik Scheme
Journal:  Front Neurorobot       Date:  2014-08-15       Impact factor: 2.650

8.  Can We Achieve Intuitive Prosthetic Elbow Control Based on Healthy Upper Limb Motor Strategies?

Authors:  Manelle Merad; Étienne de Montalivet; Amélie Touillet; Noël Martinet; Agnès Roby-Brami; Nathanaël Jarrassé
Journal:  Front Neurorobot       Date:  2018-02-02       Impact factor: 2.650

9.  Wrist-worn wearables based on force myography: on the significance of user anthropometry.

Authors:  Mona Lisa Delva; Kim Lajoie; Mahta Khoshnam; Carlo Menon
Journal:  Biomed Eng Online       Date:  2020-06-12       Impact factor: 2.819

10.  An Ultra-Sensitive Modular Hybrid EMG-FMG Sensor with Floating Electrodes.

Authors:  Ang Ke; Jian Huang; Luyao Chen; Zhaolong Gao; Jiping He
Journal:  Sensors (Basel)       Date:  2020-08-24       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.