Literature DB >> 10391350

Thoracic aortic aneurysm repair with an endovascular stent graft: the "first generation".

R S Mitchell1, D C Miller, M D Dake, C P Semba, K A Moore, T Sakai.   

Abstract

OBJECTIVE: The feasibility and efficacy trial of an endovascular stent-grafting system for the treatment of aneurysms of the descending thoracic aorta was investigated.
METHODS: After Institutional Review Board approval, 103 patients (mean age 69 years) underwent stent graft repair of a descending thoracic aortic aneurysm between July 1992 and November 1997. The stent graft was fabricated using self-expanding "Z" stents covered by a woven Dacron tube graft. Follow-up, which averaged 22 months, was 100% complete. Simultaneous open abdominal aortic aneurysm repair was performed in 19 patients.
RESULTS: Complete aneurysm thrombosis was achieved in 86 patients (83%). Early mortality, defined as a death during the same hospitalization or in less than 30 days, was 9 +/- 3%, and was significantly associated with preoperative cerebrovascular accident (CVA) or myocardial infarction. Major perioperative morbidity occurred in 31 patients, and included paraplegia in 3, CVA in 7, and respiratory insufficiency in 12 patients each. Actuarial survival was 81 +/- 4% at 1 year, and 73 +/- 5% at 2 years. Treatment failure (including all late, sudden, unexplained deaths) occurred in 38 patients, and only 53 +/- 10% of patients were free of treatment failure at 3.7 years. Five patients required late operative therapy for endoleaks associated with aneurysm enlargement.
CONCLUSIONS: Satisfactory results were achieved using this "first-generation" homemade stent graft device. Mortality and morbidity occurred frequently, but may have been associated with the high-risk character of this patient population. Medium-term results were acceptable, but continued aortic enlargement, with the late development of endoleaks, is a significant concern. Second-generation devices with commercial development, coupled with this initial experience, should allow improved clinical results in the future. Longer term follow-up is still necessary to fully define the efficacy of this endovascular approach.

Entities:  

Mesh:

Year:  1999        PMID: 10391350     DOI: 10.1016/s0003-4975(99)00436-1

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  17 in total

Review 1.  Transluminal endovascular stent grafting of aortic dissections and aneurysms: a concise review of the major trials.

Authors:  R S Dieter
Journal:  Clin Cardiol       Date:  2001-05       Impact factor: 2.882

Review 2.  Advances in thoracic aortic surgery: arch replacement with axillary cannulation and thoracic stent grafts.

Authors:  François Dagenais; Eric Dumont; Patrick Mathieu; Pierre Voisine
Journal:  Can J Cardiol       Date:  2007-10       Impact factor: 5.223

3.  A computational study on the biomechanical factors related to stent-graft models in the thoracic aorta.

Authors:  S K Lam; George S K Fung; Stephen W K Cheng; K W Chow
Journal:  Med Biol Eng Comput       Date:  2008-07-11       Impact factor: 2.602

Review 4.  An update on surgery for acute type A aortic dissection: aortic root repair, endovascular stent graft, and genetic research.

Authors:  Shinichi Suzuki; Munetaka Masuda
Journal:  Surg Today       Date:  2009-03-25       Impact factor: 2.549

5.  Endovascular repair in management of thoracic aortic aneurysms.

Authors:  Hakan Bingol; Hikmet Iyem; Hakki Tankut Akay; Bahri Ustunsoz; Cengiz Bolcal; Sahin Ugurer; Gokce Sirin; Ufuk Demirkilic; Harun Tatar
Journal:  Int J Cardiovasc Imaging       Date:  2006-06-29       Impact factor: 2.357

6.  Simultaneous total gastrectomy and endovascular repair of an abdominal aortic aneurysm: report of a case.

Authors:  Keiji Yoshinaga; Rintaro Yoshida; Atsushi Guntani; Takuya Matsumoto; Hiroshi Saeki; Masaru Morita; Yasunori Emi; Yoshihiro Kakeji; Shunichi Tsujitani; Yoshihiko Maehara
Journal:  Surg Today       Date:  2011-05-01       Impact factor: 2.549

7.  Hybrid treatment of isolated aortic arch aneurysms.

Authors:  D Laganà; G Carrafiello; D Lumia; A Ianniello; F Fontana; M Mangini; P Castelli; C Fugazzola
Journal:  Radiol Med       Date:  2009-09-22       Impact factor: 3.469

8.  Aortoesophageal fistula: value of in situ aortic allograft replacement.

Authors:  Edouard Kieffer; Laurent Chiche; Dominique Gomes
Journal:  Ann Surg       Date:  2003-08       Impact factor: 12.969

9.  Midterm results of endovascular stent graft treatment for descending aortic aneurysms including high-risk patients.

Authors:  Roland H Wagner; Jörg Krenzien; Andreas Gussmann
Journal:  Ger Med Sci       Date:  2006-04-12

10.  Hybrid procedures as a combined endovascular and open approach for pararenal and thoracoabdominal aortic pathologies.

Authors:  Dittmar Böckler; Hardy Schumacher; Klaus Klemm; Marcel Riemensperger; Philipp Geisbüsch; Drosos Kotelis; Harry Rotert; Jens-Rainer Allenberg
Journal:  Langenbecks Arch Surg       Date:  2007-05-26       Impact factor: 3.445

View more