Literature DB >> 10389780

A controlled study of transesophageal echocardiography to guide central venous catheter placement in congenital heart surgery patients.

D B Andropoulos1, S A Stayer, S T Bent, C J Campos, L I Bezold, M Alvarez, C D Fraser.   

Abstract

UNLABELLED: Transesophageal echocardiography (TEE) and central venous catheter (CVC) placement are often used during congenital cardiac surgery. Complications of CVC placement include cardiac perforation, inadvertent arterial placement, and erroneous hemodynamic data from unrecognized malposition. In this study, we used a prospective, randomized, controlled design to evaluate the use of TEE to guide depth of insertion and confirm superior vena cava cannulation, and to improve the percentage of correctly placed CVCs and reduce complications of CVC placement. One hundred forty-five patients were studied. Eighty patients were randomized to have subclavian vein insertion, 64 to have internal jugular insertion, and 1 to have external jugular insertion of CVC. TEE-guided CVC placement resulted in 100% correct placement when assessed by preoperative TEE, versus 86% in the control group (72 of 72 vs. 63 of 73; P = 0.01). There was no difference in correct placement between the two groups when assessed by postoperative chest radiograph (81.9% TEE versus 75.3% control; P = not significant). One significant complication, a superior vena cava perforation, occurred in the control group. Time to placement was 9.6 min in the TEE group versus 8.0 min in the control group (P = 0.015). IMPLICATIONS: Transesophageal echocardiography can be used to guide central venous catheter placement in congenital heart surgery. Central venous catheters that seem to be located high in the right atrium by chest radiograph in these patients are often actually in the superior vena cava and pose little risk of cardiac perforation.

Entities:  

Mesh:

Year:  1999        PMID: 10389780     DOI: 10.1097/00000539-199907000-00012

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  16 in total

1.  Use of hand-held ultrasonography to confirm the correct placement of a central venous catheter tip.

Authors:  Tomoyuki Ohta; Fumio Tsujimoto; Yasuo Nakajima; Akihiro Ohyama; Maho Sakamoto; Akiko Kishino; Kazumitsu Hamasuna; Giichiro Ohno; Atsushi Tsugu
Journal:  J Med Ultrason (2001)       Date:  2007-03-15       Impact factor: 1.314

2.  [Modified ECG-guidance for optimal central venous catheter tip positioning. A transesophageal echocardiography controlled study].

Authors:  W Schummer; C Schummer; C Schelenz; P Schmidt; R Fröber; E Hüttemann
Journal:  Anaesthesist       Date:  2005-10       Impact factor: 1.041

3.  A CT scan-based formula for predicting central venous catheter length in pediatric patients.

Authors:  Aaron B Ross; Oswaldo Gomez-Quevedo; Pattamon Sutthatarn; Zhaohua Lu; Xiaoqing Wang; Hasmukh Prajapati; Lindsay J Talbot; Andrew M Davidoff; Andrew J Murphy; Abdelhafeez H Abdelhafeez
Journal:  Pediatr Surg Int       Date:  2022-07-18       Impact factor: 2.003

4.  The mid-sternal length, a practical anatomical landmark for optimal positioning of long-term central venous catheters.

Authors:  Fereshte Salimi; Mohammad Reza Imani; Navab Ghasemi; Amir Keshavarzian; Amir Hosein Davarpanah Jazi
Journal:  J Res Med Sci       Date:  2013-05       Impact factor: 1.852

5.  Bedside prediction of the central venous catheter insertion depth - Comparison of different techniques.

Authors:  Jayaprakash Jayaraman; Veena Shah
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2019 Apr-Jun

6.  Optimal positioning of right-sided internal jugular venous catheters: comparison of intra-atrial electrocardiography versus Peres' formula.

Authors:  Anish M Joshi; Guruprasad P Bhosale; Geeta P Parikh; Veena R Shah
Journal:  Indian J Crit Care Med       Date:  2008-01

7.  Role of chest X-ray in citing central venous catheter tip: A few case reports with a brief review of the literature.

Authors:  Achuthan Nair Venugopal; Rachel Cherian Koshy; Sumod M Koshy
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-07

8.  Factors Influencing Intracavitary Electrocardiographic P-Wave Changes during Central Venous Catheter Placement.

Authors:  Guorong Wang; Ling Guo; Bin Jiang; Min Huang; Jian Zhang; Ying Qin
Journal:  PLoS One       Date:  2015-04-27       Impact factor: 3.240

9.  Depth of insertion of right internal jugular central venous catheter: Comparison of topographic and formula methods.

Authors:  M Vinay; C A Tejesh
Journal:  Saudi J Anaesth       Date:  2016 Jul-Sep

10.  Practical anatomical landmark for optimal positioning of left-sided long-term central venous catheter (a pilot study).

Authors:  Fereshteh Salimi; Amirreza Sajjadieh Khajouei; Saeed Keighobadi; Amir Keshavarzian
Journal:  J Res Med Sci       Date:  2020-03-18       Impact factor: 1.852

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.