Literature DB >> 10388369

Microleakage of Class II box-type composite restorations.

N J Opdam1, J J Roeters, R C Burgersdijk.   

Abstract

PURPOSE: To investigate whether in small box-type Class II preparations the use of glass ionomer cement, a dentin primer or a different type of conditioner had an effect on the microleakage compared to a more simple total-etch system using a phosphonated bonding agent.
MATERIALS AND METHODS: In extracted premolars, 84 box-type Class II composite resin restorations with margins in enamel were made following a standardized protocol. A transparent matrix system was used and the composite resin was applied in two layers. The teeth were restored using a phosphonated total-etch bonding system as a control (Photo Bond). In the experimental groups a glass ionomer lining-cement (Vitrebond), a total-etch adhesive including a primer (Scotchbond Multi-Purpose) and a total-etch adhesive using a self-etching primer (Liner Bond 2) were used. The teeth were thermocycled, immersed in a dye solution and sectioned. The cervical and occlusal dye penetration was assessed.
RESULTS: Preventing microleakage was not more effective in the experimental groups than in the control group (P < 0.05). Scotchbond MP groups using maleic acid showed statistically significant more microleakage than the control group (Photo Bond) at the cervical side. Liner Bond 2 and Scotchbond MP groups using maleic acid showed statistically significant more microleakage than the control group at the occlusal side. The use of a lining cement did not improve the quality of the restoration. From this study it was concluded that in this type of restoration, total-etch systems using a primer are not always an improvement.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10388369

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  2 in total

1.  Microleakage and Resin-to-Dentin Interface Morphology of Pre-Etching versus Self-Etching Adhesive Systems.

Authors:  G L Waldman; T K Vaidyanathan; J Vaidyanathan
Journal:  Open Dent J       Date:  2008-11-28

2.  Evaluation of Microleakage in Class II Cavities using Packable Composite Restorations with and without use of Liners.

Authors:  Rajesh Arora; Ravi Kapur; Nikhil Sibal; Sumit Juneja
Journal:  Int J Clin Pediatr Dent       Date:  2012-12-05
  2 in total