Literature DB >> 10385291

A new approach for nonlinear distortion correction in endoscopic images based on least squares estimation.

K V Asari1, S Kumar, D Radhakrishnan.   

Abstract

Images captured with a typical endoscope show spatial distortion, which necessitates distortion correction for subsequent analysis. In this paper, a new methodology based on least squares estimation is proposed to correct the nonlinear distortion in the endoscopic images. A mathematical model based on polynomial mapping is used to map the images from distorted image space onto the corrected image space. The model parameters include the polynomial coefficients, distortion center, and corrected center. The proposed method utilizes a line search approach of global convergence for the iterative procedure to obtain the optimum expansion coefficients. A new technique to find the distortion center of the image based on curvature criterion is presented. A dual-step approach comprising token matching and integrated neighborhood search is also proposed for accurate extraction of the centers of the dots contained in a rectangular grid, used for the model parameter estimation. The model parameters were verified with different grid patterns. The distortion-correction model is applied to several gastrointestinal images and the results are presented. The proposed technique provides high-speed response and forms a key step toward online camera calibration, which is required for accurate quantitative analysis of the images.

Mesh:

Year:  1999        PMID: 10385291     DOI: 10.1109/42.768843

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  11 in total

1.  Foveated endoscopic lens.

Authors:  Nathan Hagen; Tomasz S Tkaczyk
Journal:  J Biomed Opt       Date:  2012-02       Impact factor: 3.170

2.  Methods for removing glare in digital endoscope images.

Authors:  Eric Abel; Wei Xi; Paul White
Journal:  Surg Endosc       Date:  2011-09-30       Impact factor: 4.584

3.  Low-distortion perturbative solutions in a camera calibration model including high-distortion radial effects.

Authors:  Matteo Ciucci; Daniel Stein; Joerg Raczkowsky; Heinz Wörn
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-05-23       Impact factor: 2.924

4.  Development of a microbial high-throughput screening instrument based on elastic light scatter patterns.

Authors:  Euiwon Bae; Valery Patsekin; Bartek Rajwa; Arun K Bhunia; Cheryl Holdman; V Jo Davisson; E Daniel Hirleman; J Paul Robinson
Journal:  Rev Sci Instrum       Date:  2012-04       Impact factor: 1.523

5.  Integrated CT/bronchoscopy in the central airways: preliminary results.

Authors:  Melissa J Suter; Joseph M Reinhardt; Geoffrey McLennan
Journal:  Acad Radiol       Date:  2008-06       Impact factor: 3.173

6.  Loading and boundary condition influences in a poroelastic finite element model of cartilage stresses in a triaxial compression bioreactor.

Authors:  Nicole A Kallemeyn; Nicole M Grosland; Doug R Pedersen; James A Martin; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2006

7.  Computer-based System for the Virtual-Endoscopic Guidance of Bronchoscopy.

Authors:  J P Helferty; A J Sherbondy; A P Kiraly; W E Higgins
Journal:  Comput Vis Image Underst       Date:  2007-11       Impact factor: 3.876

8.  Arthroscopic lens distortion correction applied to dynamic cartilage loading.

Authors:  Nicole A Kallemeyn; Nicole M Grosland; Wincent A Magnotta; James A Martin; Douglas R Pedersen
Journal:  Iowa Orthop J       Date:  2007

9.  Short Circuit Recognition for Metal Electrorefining Using an Improved Faster R-CNN With Synthetic Infrared Images.

Authors:  Xin Li; Yonggang Li; Renchao Wu; Can Zhou; Hongqiu Zhu
Journal:  Front Neurorobot       Date:  2021-11-26       Impact factor: 2.650

10.  Evaluation of different distortion correction methods and interpolation techniques for an automated classification of celiac disease.

Authors:  M Gadermayr; M Liedlgruber; A Uhl; A Vécsei
Journal:  Comput Methods Programs Biomed       Date:  2013-08-24       Impact factor: 5.428

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.