Literature DB >> 10383077

A comparison of ELISA assays as routine diagnostic test for detection of autoantibodies against extractable nuclear antigens.

H L Van Duijnhoven1, F J Van De Warenburg, R J Willems, A M Ermens.   

Abstract

OBJECTIVE: In an analytical evaluation, commercially available ELISA test kits for detection of antibodies directed against extractable nuclear antigens (ENA) were compared with the currently used combination of counterimmunoelectrophoresis and immunoblotting.
DESIGN: Three screening ELISAs and two typing ELISAs were tested. These methods were fairly simple, easy to perform and "user friendly," because most of the reagents were ready to use.
RESULTS: The agreement with the current methods was good, but the screening as well as typing ELISAs proved to be more sensitive, especially with regard to detection of SS-A auto-antibodies. The cut-off range of one screening assay was not well established and one typing assay suffered from problems with inaccuracy of package insert, purity of antigen and standardisation of reactivity (possibly caused by differences in amount of coated antigen). The other three ELISAs were reliable and sensitive for detection of ENA auto-antibodies.
CONCLUSIONS: The ELISA ENA screen assays ENA-LISA polyvalent and Milenia ENA screen and typing assays ENA-LISA are reliable and sensitive for detection of autoantibodies in clinical specimens without substantial false negatives.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10383077     DOI: 10.1016/s0009-9120(99)00006-5

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  6 in total

1.  Antibodies to extractable nuclear antigens. Has technological drift affected clinical interpretation?

Authors:  R J Lock; D J Unsworth
Journal:  J Clin Pathol       Date:  2001-03       Impact factor: 3.411

Review 2.  Autoantibodies to extractable nuclear antigens: making detection and interpretation more meaningful.

Authors:  Tri Giang Phan; Richard C W Wong; Stephen Adelstein
Journal:  Clin Diagn Lab Immunol       Date:  2002-01

3.  Practical evaluation of methods for detection and specificity of autoantibodies to extractable nuclear antigens.

Authors:  Susan M Orton; Amy Peace-Brewer; John L Schmitz; Kristie Freeman; William C Miller; James D Folds
Journal:  Clin Diagn Lab Immunol       Date:  2004-03

4.  Clinical associations of anti-Smith antibodies in PROFILE: a multi-ethnic lupus cohort.

Authors:  Mariangelí Arroyo-Ávila; Yesenia Santiago-Casas; Gerald McGwin; Ryan S Cantor; Michelle Petri; Rosalind Ramsey-Goldman; John D Reveille; Robert P Kimberly; Graciela S Alarcón; Luis M Vilá; Elizabeth E Brown
Journal:  Clin Rheumatol       Date:  2015-04-22       Impact factor: 2.980

5.  Evaluation of multiplexed fluorescent microsphere immunoassay for detection of autoantibodies to nuclear antigens.

Authors:  Thomas B Martins; Rufus Burlingame; Carlos A von Mühlen; Troy D Jaskowski; Christine M Litwin; Harry R Hill
Journal:  Clin Diagn Lab Immunol       Date:  2004-11

6.  Interkit Reproducibility of the Indirect Immunofluorescence Assay on HEp-2 Cells Depends on the Immunofluorescence Reactivity Intensity and Pattern.

Authors:  Mônica Jesus Silva; Alessandra Dellavance; Danielle Cristiane Baldo; Silvia Helena Rodrigues; Marcelle Grecco; Monica Simon Prado; Renan Agustinelli; Luís Eduardo Coelho Andrade
Journal:  Front Immunol       Date:  2022-01-19       Impact factor: 7.561

  6 in total