Literature DB >> 10382830

Mechanical loading of bovine pericardium accelerates enzymatic degradation.

J C Ellsmere1, R A Khanna, J M Lee.   

Abstract

Bioprosthetic heart valves fail as the result of two simultaneous processes: structural deterioration and calcification. Leaflet deterioration and perforation have been correlated with regions of highest stress in the tissue. The failures have long been assumed to be due to simple mechanical fatigue of the collagen fibre architecture; however, we have hypothesized that local stresses-and particularly dynamic stresses-accelerate local proteolysis, leading to tissue failure. This study addresses that hypothesis. Using a novel, custom-built microtensile culture system, strips of bovine pericardium were subjected to static and dynamic loads while being exposed to solutions of microbial collagenase or trypsin (a non-specific proteolytic enzyme). The time to extend to 30% strain (defined here as time to failure) was recorded. After failure, the percentage of collagen solubilized was calculated based on the amount of hydroxyproline present in solution. All data were analyzed by analysis of variance (ANOVA). In collagenase, exposure to static load significantly decreased the time to failure (P < 0.002) due to increased mean rate of collagen solubilization. Importantly, specimens exposed to collagenase and dynamic load failed faster than those exposed to collagenase under the same average static load (P = 0.02). In trypsin, by contrast, static load never led to failure and produced only minimal degradation. Under dynamic load, however, specimens exposed to collagenase, trypsin, and even Tris/CaCl2 buffer solution, all failed. Only samples exposed to Hanks' physiological solution did not fail. Failure of the specimens exposed to trypsin and Tris/CaCl2 suggests that the non-collagenous components and the calcium-dependent proteolytic enzymes present in pericardial tissue may play roles in the pathogenesis of bioprosthetic heart valve degeneration.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10382830     DOI: 10.1016/s0142-9612(99)00013-7

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  16 in total

1.  Molecular mechanism of force induced stabilization of collagen against enzymatic breakdown.

Authors:  Shu-Wei Chang; Brendan P Flynn; Jeffrey W Ruberti; Markus J Buehler
Journal:  Biomaterials       Date:  2012-03-06       Impact factor: 12.479

2.  Micromechanical Modeling Study of Mechanical Inhibition of Enzymatic Degradation of Collagen Tissues.

Authors:  Theresa K Tonge; Jeffrey W Ruberti; Thao D Nguyen
Journal:  Biophys J       Date:  2015-12-15       Impact factor: 4.033

3.  In-vivo stretch of term human fetal membranes.

Authors:  E M Joyce; P Diaz; S Tamarkin; R Moore; A Strohl; B Stetzer; D Kumar; M S Sacks; J J Moore
Journal:  Placenta       Date:  2015-12-20       Impact factor: 3.481

4.  Multiplexed single-molecule force proteolysis measurements using magnetic tweezers.

Authors:  Arjun S Adhikari; Jack Chai; Alexander R Dunn
Journal:  J Vis Exp       Date:  2012-07-25       Impact factor: 1.355

Review 5.  Introduction to cell-hydrogel mechanosensing.

Authors:  Mark Ahearne
Journal:  Interface Focus       Date:  2014-04-06       Impact factor: 3.906

Review 6.  The physics of cancer: the role of physical interactions and mechanical forces in metastasis.

Authors:  Denis Wirtz; Konstantinos Konstantopoulos; Peter C Searson
Journal:  Nat Rev Cancer       Date:  2011-06-24       Impact factor: 60.716

7.  Assessment of decellularized pericardial extracellular matrix and poly(propylene fumarate) biohybrid for small-diameter vascular graft applications.

Authors:  Megan Kimicata; Jules D Allbritton-King; Javier Navarro; Marco Santoro; Takahiro Inoue; Narutoshi Hibino; John P Fisher
Journal:  Acta Biomater       Date:  2020-04-16       Impact factor: 8.947

8.  Parameter sensitivity study of a constrained mixture model of arterial growth and remodeling.

Authors:  A Valentín; J D Humphrey
Journal:  J Biomech Eng       Date:  2009-10       Impact factor: 2.097

9.  Mechanical strain stabilizes reconstituted collagen fibrils against enzymatic degradation by mammalian collagenase matrix metalloproteinase 8 (MMP-8).

Authors:  Brendan P Flynn; Amit P Bhole; Nima Saeidi; Melody Liles; Charles A Dimarzio; Jeffrey W Ruberti
Journal:  PLoS One       Date:  2010-08-23       Impact factor: 3.240

Review 10.  Biomechanics of the fetal membrane prior to mechanical failure: review and implications.

Authors:  Erinn M Joyce; John J Moore; Michael S Sacks
Journal:  Eur J Obstet Gynecol Reprod Biol       Date:  2009-03-19       Impact factor: 2.435