Respective roles of scatter, attenuation, depth-dependent collimator response and finite spatial resolution in cardiac single-photon emission tomography quantitation: a Monte Carlo study.

G N el Fakhri1, I Buvat, M Pélégrini, H Benali, P Almeida, B Bendriem, A Todd-Pokropek, R Di Paola.   

Abstract

The purpose of this study was to investigate the relative influence of scatter, attenuation, depth-dependent collimator response and finite spatial resolution upon the image characteristics in cardiac single-photon emission tomography (SPET). An acquisition of an anthropomorphic cardiac phantom was performed together with corresponding SPET Monte Carlo simulations. The cardiac phantom and the Monte Carlo simulations were designed so that the effect of scatter, attenuation, depth-dependent collimator response and finite spatial resolution could be studied individually and in combination. The impact of each physical effect and of combinations of effects was studied in terms of absolute and relative quantitative accuracy, spatial resolution and signal-to-noise ratio (SNR) in the resulting images. No corrections for these effects were assessed. Results obtained from Monte Carlo simulations and real acquisitions were in excellent agreement. Attenuation introduced about 90% activity underestimation in a 10-mm-thick left ventricle wall while finite spatial resolution alone introduced about 30% activity underestimation. Scatter had a negligible impact on quantitative accuracy in the recontructed slices when attenuation was present. Neither bull's eye map homogeneity nor contrast between a hot and a cold region were affected by depth-dependent collimator response or finite spatial resolution. Bull's eye map homogeneity was severely affected by attenuation but not by scatter. Attenuation and scatter reduced contrast by about 20% each. Both attenuation and scatter increased the full-width at half-maximum (FWHM) characterizing the spatial resolution of the imaging system by approximately 1 mm each but the main effect responsible for the observed 11-mm FWHM spatial resolution was the depth-dependent collimator response. SNR was reduced by a factor of approximately 2.5 because of attenuation, while scattered counts increased SNR by approximately 10%. In conclusion, the quantification of the relative influence of the different physical effects showed that attenuation is definitely the major phenomenon affecting cardiac SPET imaging accuracy, but that finite spatial resolution, scatter and depth-dependent collimator response also contribute significantly to the errors in absolute and relative quantitation and to the poor spatial resolution.

Mesh:

Year:  1999        PMID: 10382086     DOI: 10.1007/s002590050409

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  7 in total

1.  Assessment of geometrical distortion and activity distribution after attenuation correction: A SPECT phantom study.

Authors:  Sara Lappi; Simonetta Lazzari; Graziella Sarti; Pierluigi Pieri
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

2.  A publicly accessible Monte Carlo database for validation purposes in emission tomography.

Authors:  I Castiglioni; I Buvat; G Rizzo; M C Gilardi; J Feuardent; F Fazio
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07-02       Impact factor: 9.236

Review 3.  Absolute quantification in SPECT.

Authors:  Philipp Ritt; Hans Vija; Joachim Hornegger; Torsten Kuwert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

4.  Image quantification for radiation dose calculations--limitations and uncertainties.

Authors:  J M Pereira; M G Stabin; F R A Lima; M I C C Guimarães; J W Forrester
Journal:  Health Phys       Date:  2010-11       Impact factor: 1.316

5.  Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: a multicenter trial.

Authors:  J M Links; L C Becker; P Rigo; R Taillefer; L Hanelin; F Anstett; D Burckhardt; L Mixon
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

6.  A new method to correct the attenuation map in simultaneous transmission/emission tomography using Gd/Ga radioisotopes.

Authors:  Subhash Chand Kheruka; Brian F Hutton; Umesh Chand Naithani; Lalit Mohan Aggarwal; Nirmal Kumar Painuly; Anil Kumar Maurya; Sanjay Gambhir
Journal:  J Med Phys       Date:  2012-01

Review 7.  Hybrid Imaging for Patient-Specific Dosimetry in Radionuclide Therapy.

Authors:  Michael Ljungberg; Katarina Sjögreen Gleisner
Journal:  Diagnostics (Basel)       Date:  2015-07-10