Literature DB >> 10379252

Comparison of three fracture toughness testing techniques using a dental glass and a dental ceramic.

S S Scherrer1, I L Denry, H W Wiskott.   

Abstract

OBJECTIVES: Various methods aimed at determining the fracture toughness of ceramics in mode I (KIc) have been described in the literature. The accuracy, scatter and the interexaminer reproducibility of KIc depend strongly on the procedural approach, the test parameters used and the conditioning of the specimens. The purpose of the present study was to compare fracture toughness values obtained using two indentation methods as well as a newly established fracture mechanics test.
METHODS: The following methods for KIc determination were applied: (1) indentation fracture (IF), (2) indentation strength (IS) and (3) the single-edge-V-notched-beam test (SEVNB). The materials tested were a low-fusing dental glass (Duceram LFC) and a feldspar-based porcelain (IPS classic). Data were compared by ANOVA and Tukey's multiple comparison test (p < or = 0.05).
RESULTS: For both materials, KIc coefficients of variation ranged between 10 and 14% for IF and 7 and 10% for IS. The IS technique demonstrated a load dependency for the IPS porcelain which was not observed when using the IF method. The SEVNB test provided consistent results with coefficients of variation between 1 and 3%. SEVNB toughness values for the IPS porcelain were in agreement with the IS technique. However, halfpenny shaped cracks were observed at the tip of the notch of all LFC specimens thus leading to underestimated KIc values. SIGNIFICANCE: The overall aim of this type of study is to select testing procedures that are as expedient and reliable as possible. This study has shown that all three methods agreed within 10%. However none of the procedures proved absolutely straightforward. Decision on which method to use should be based on a sound understanding of the conceptual limitations and technical difficulties inherent to each technique.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10379252     DOI: 10.1016/s0109-5641(98)00032-3

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  6 in total

1.  Influence of cyclic loading on the fracture toughness and load bearing capacities of all-ceramic crowns.

Authors:  Rao-Rao Wang; Cheng-Lin Lu; Gang Wang; Dong-Sheng Zhang
Journal:  Int J Oral Sci       Date:  2013-12-13       Impact factor: 6.344

2.  Fracture toughness of different monolithic zirconia upon post-sintering processes.

Authors:  Niwut Juntavee; Apa Juntavee; Thipradi Phattharasophachai
Journal:  J Clin Exp Dent       Date:  2021-10-01

3.  Characterization of a polymer-infiltrated ceramic-network material.

Authors:  Alvaro Della Bona; Pedro H Corazza; Yu Zhang
Journal:  Dent Mater       Date:  2014-03-20       Impact factor: 5.304

4.  Fatigue loading and R-curve behavior of a dental glass-ceramic with multiple flaw distributions.

Authors:  Gaurav V Joshi; Yuanyuan Duan; Alvaro Della Bona; Thomas J Hill; Kenneth St John; Jason A Griggs
Journal:  Dent Mater       Date:  2013-09-10       Impact factor: 5.304

5.  Comparison of two fracture toughness testing methods using a glass-infiltrated and a zirconia dental ceramic.

Authors:  Premwara Triwatana; Phakphum Srinuan; Kallaya Suputtamongkol
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

6.  Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study.

Authors:  Hadi Mokhtarpour; Reza Eftekhar Ashtiani; Minoo Mahshid; Farhad Tabatabaian; Marzieh Alikhasi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-08-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.