Clinical audit of 5 years provision of the Odstock dropped foot stimulator.

P Taylor1, J Burridge, A Dunkerley, D Wood, J Norton, C Singleton, I Swain.   

Abstract

The Odstock dropped foot stimulator (ODFS) is a foot switch controlled single channel neuromuscular stimulator for correction of dropped foot. Following a randomized controlled trial, the ODFS was recommended for use in the United Kingdom's National Health Service and a clinical service established. The patient performance was assessed by measurement of walking speed over 10 m, physiological cost index (PCI), and by questionnaire. After 4.5 months stroke patients (n = 111) showed a mean increase in walking speed of 27% and reduction in PCI of 31% with stimulation and changes of 14% and 19%, respectively, unassisted. Multiple sclerosis patients (n = 21) gained similar orthotic benefit but no carry over. The principal reason cited for using the equipment was that it reduced the effort of walking. The principal reasons identified for discontinuing were an improvement in mobility, electrode positioning difficulties, and deteriorating mobility. A comprehensive clinical follow-up service is essential to achieve the maximum continuing benefit from FES based orthosis.

Entities:  

Mesh:

Year:  1999        PMID: 10378938     DOI: 10.1046/j.1525-1594.1999.06374.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  4 in total

Review 1.  Position-sensing technologies for movement analysis in stroke rehabilitation.

Authors:  H Zheng; N D Black; N D Harris
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

2.  Spatiotemporal, kinematic, and kinetic effects of a peroneal nerve stimulator versus an ankle foot orthosis in hemiparetic gait.

Authors:  Lynne R Sheffler; Stephanie Nogan Bailey; Richard D Wilson; John Chae
Journal:  Neurorehabil Neural Repair       Date:  2012-11-27       Impact factor: 3.919

3.  Dual-channel functional electrical stimulation improvements in speed-based gait classifications.

Authors:  Shmuel Springer; Yocheved Laufer; Meni Becher; Jean-Jacques Vatine
Journal:  Clin Interv Aging       Date:  2013-02-28       Impact factor: 4.458

4.  A decision support system for electrode shaping in multi-pad FES foot drop correction.

Authors:  Jovana Malešević; Suzana Dedijer Dujović; Andrej M Savić; Ljubica Konstantinović; Aleksandra Vidaković; Goran Bijelić; Nebojša Malešević; Thierry Keller
Journal:  J Neuroeng Rehabil       Date:  2017-07-03       Impact factor: 4.262

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.