Literature DB >> 10376066

Automated calculation of the centerline of the human colon on CT images.

Y Samara1, M Fiebich, A H Dachman, J K Kuniyoshi, K Doi, K R Hoffmann.   

Abstract

RATIONALE AND
OBJECTIVES: This article presents an evaluation of an automated technique for determining the colon centerline with computed tomographic (CT) data sets.
MATERIALS AND METHODS: The technique proceeds as follows. After indication of a voxel in the rectum, voxels corresponding to air were segmented. Points along the colon centerline were estimated on the basis of centers of mass of grown voxels. A second segmentation and centerline calculation was initiated at the cecum. These two centerlines were then averaged. The resulting average was refined by using lumen data obtained perpendicular to the average centerline. The accuracy of the technique was investigated with simulation phantoms. The technique was also evaluated for 40 clinical colon cases. Calculated centerline points were compared with those indicated by radiologists for a randomly selected clinical case.
RESULTS: In the simulation studies, the calculated centerline points were, on average, within 2.5 mm of the true centerlines but differed by up to 4 mm in regions of deep folds or sharp turns. In the clinical colon study, 40% of the centerlines were computed with a single seed point and 25% with two seed points. Average centerlines were computed in 1 minute. The root mean square difference between the computed centerline points and those indicated by the radiologists was 4-5 mm (comparable to interobserver variations).
CONCLUSION: Accurate centerlines can be determined from colon CT data with this automated technique.

Entities:  

Mesh:

Year:  1999        PMID: 10376066     DOI: 10.1016/s1076-6332(99)80230-x

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  4 in total

1.  Real-time endovascular guidewire position simulation using shortest path algorithms.

Authors:  Sebastian Schafer; Vikas Singh; Peter B Noël; Alan M Walczak; Jinhui Xu; Kenneth R Hoffmann
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-07-18       Impact factor: 2.924

2.  Evaluation of guidewire path reproducibility.

Authors:  Sebastian Schafer; Kenneth R Hoffmann; Peter B Noël; Ciprian N Ionita; Jacek Dmochowski
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

3.  NONLINEAR TUBE-FITTING FOR THE ANALYSIS OF ANATOMICAL AND FUNCTIONAL STRUCTURES.

Authors:  Jeff Goldsmith; Brian Caffo; Ciprian Crainiceanu; Daniel Reich; Yong Du; Craig Hendrix
Journal:  Ann Appl Stat       Date:  2011-01-01       Impact factor: 2.083

4.  A nonparametric shape prior constrained active contour model for segmentation of coronaries in CTA images.

Authors:  Yin Wang; Han Jiang
Journal:  Comput Math Methods Med       Date:  2014-04-01       Impact factor: 2.238

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.