Literature DB >> 10374829

Incorporating a priori anatomical information into image reconstruction in electrical impedance tomography.

H Dehghani1, D C Barber, I Basarab-Horwath.   

Abstract

Image reconstruction in electrical impedance tomography using the sensitivity theorem is generally based on the assumption that the initial conductivity distribution of the body being imaged is uniform. The technique of image reconstruction using this method is described and reconstructed images are presented. Improvements in image quality and accuracy are demonstrated when accurate a priori 'anatomical' information, in the form of a model of the distribution of conductivity within the region to be imaged, is used to construct the sensitivity matrix. In practice correct a priori information is not available, for example the conductivity values within the various anatomical regions will not be known. An iterative algorithm is presented which allows the conductivity parameters of the a priori model to be determined during reconstruction.

Mesh:

Year:  1999        PMID: 10374829     DOI: 10.1088/0967-3334/20/1/007

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  7 in total

1.  Incorporating a Spatial Prior into Nonlinear D-Bar EIT Imaging for Complex Admittivities.

Authors:  Sarah J Hamilton; J L Mueller; M Alsaker
Journal:  IEEE Trans Med Imaging       Date:  2016-09-26       Impact factor: 10.048

2.  Calderón's Method with a Spatial Prior for 2-D EIT Imaging of Ventilation and Perfusion.

Authors:  Kwancheol Shin; Jennifer L Mueller
Journal:  Sensors (Basel)       Date:  2021-08-21       Impact factor: 3.847

3.  DYNAMIC OPTIMIZED PRIORS FOR D-BAR RECONSTRUCTIONS OF HUMAN VENTILATION USING ELECTRICAL IMPEDANCE TOMOGRAPHY.

Authors:  Melody Alsaker; Jennifer L Mueller; Rashmi Murthy
Journal:  J Comput Appl Math       Date:  2018-08-13       Impact factor: 2.621

4.  Combing signal processing methods with algorithm priori information to produce synergetic improvements on continuous imaging of brain electrical impedance tomography.

Authors:  Haoting Li; Rongqing Chen; Canhua Xu; Benyuan Liu; Xiuzhen Dong; Feng Fu
Journal:  Sci Rep       Date:  2018-07-04       Impact factor: 4.379

5.  Improved resolution of D-bar images of ventilation using a Schur complement property and an anatomical atlas.

Authors:  Talles Batista Rattis Santos; Rafael Mikio Nakanishi; Erick Dario León Bueno de Camargo; Marcelo Brito Passos Amato; Jari P Kaipio; Raul Gonzalez Lima; Jennifer L Mueller
Journal:  Med Phys       Date:  2022-05-05       Impact factor: 4.506

6.  Complementary use of priors for pulmonary imaging with electrical impedance and ultrasound computed tomography.

Authors:  Melody Alsaker; Diego Armando Cardona Cárdenas; Sérgio Shiguemi Furuie; Jennifer L Mueller
Journal:  J Comput Appl Math       Date:  2021-04-20       Impact factor: 2.872

7.  Introduction of Sample Based Prior into the D-Bar Method Through a Schur Complement Property.

Authors:  Talles Batista Rattis Santos; Rafael Mikio Nakanishi; Jari P Kaipio; Jennifer L Mueller; Raul Gonzalez Lima
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 11.037

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.