Literature DB >> 10372621

One or two lag screws for fixation of Danis-Weber type B fractures of the ankle.

S K Kim1, J K Oh.   

Abstract

BACKGROUND: There are many limitations in using the plate for fixation of lateral malleolar fractures of the ankle.
METHODS: This study prospectively reviewed 60 of 72 consecutive patients with an average follow up of 3.8 years who had Danis-Weber type B ankle fractures that were treated with one or two 3.5-mm cortical lag screws without plate fixation.
RESULTS: A stable anatomic reduction was obtained in 57 cases (95%). The average time to healing by radiograph was 3.1 months. There were two delayed unions and no nonunions. Joint space narrowing was found in one case. Clinical assessment was satisfactory in 56 of the patients (93%).
CONCLUSION: Noncomminuted Danis-Weber Type B ankle fractures can be successfully treated without the risk of lateral plating, which includes cartilage damage caused by penetration of the ankle joint, increased periosteal dissection, and the risk of subsequent hardware removal.

Entities:  

Mesh:

Year:  1999        PMID: 10372621     DOI: 10.1097/00005373-199906000-00010

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  6 in total

1.  Less is more: lag screw only fixation of lateral malleolar fractures.

Authors:  Paul B McKenna; Kieran O'shea; Tom Burke
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

2.  Lateral fixation of open AO type-B2 ankle fractures: the Knowles pin versus plate.

Authors:  Yih-Shiunn Lee; Shu-Wen Chen
Journal:  Int Orthop       Date:  2008-07-11       Impact factor: 3.075

3.  Distal fibula oblique fracture fixation using one-third tubular plate with and without lag screw - A biomechanical study of stability.

Authors:  Gopikanthan Manoharan; Rohit Singh; Jan Herman Kuiper; Leonard Derek Martin Nokes
Journal:  J Orthop       Date:  2018-05-07

4.  Lateral fixation of AO type-B2 ankle fractures: the Acutrak plus compression screw technique.

Authors:  Yih-Shiunn Lee; Tzu-Liang Hsu; Chien-Rae Huang; Shih-Hao Chen
Journal:  Int Orthop       Date:  2010-02-23       Impact factor: 3.075

5.  One-Third Tubular Plate Remains a Clinically Good Option in Danis-Weber Type B Distal Fibular Fracture Fixation.

Authors:  Jae Hoon Ahn; Sung Hyun Cho; Mingi Jeong; Yoon-Chung Kim
Journal:  Orthop Surg       Date:  2021-10-27       Impact factor: 2.071

6.  A comparative study in fixation methods of medial malleolus fractures between tension bands wiring and screw fixation.

Authors:  Ayyoub A Mohammed; Khalid Ahmed Abbas; Ammar Salah Mawlood
Journal:  Springerplus       Date:  2016-04-26