Literature DB >> 10372174

Orientation and deformation of erythrocytes in flowing blood.

M Fujii1, K Nakajima, K Sakamoto, H Kanai.   

Abstract

The effects of flow on the changes of electrical resistivity and light-scattering characteristics of blood are experimentally and theoretically discussed. Studies indicate that most erythrocytes deform and orient themselves in the flow direction when blood flows in a conduit. Such oriented blood shows anisotropic properties. Anisotropic electrical resistivity of flowing blood is measured in three rectangular directions with a measurement cell of coaxial cylindrical type. From these experimental results, the orientation and deformation of erythrocytes are discussed. The orientation ratio and the deformation are calculated using a simplified spheroidal model of an erythrocyte. Calculated results show that the fractions of erythrocytes with their short axis parallel to each direction and the equivalent axis ratio for a simplified spheroidal model change with the shear rate of flow.

Mesh:

Year:  1999        PMID: 10372174     DOI: 10.1111/j.1749-6632.1999.tb09473.x

Source DB:  PubMed          Journal:  Ann N Y Acad Sci        ISSN: 0077-8923            Impact factor:   5.691


  6 in total

1.  Non-invasive continuous estimation of blood flow changes in human patellar bone.

Authors:  Jan Näslund; Jonas Pettersson; Thomas Lundeberg; Dag Linnarsson; Lars-Göran Lindberg
Journal:  Med Biol Eng Comput       Date:  2006-06-03       Impact factor: 2.602

2.  Physiological quality assessment of stored whole blood by means of electrical measurements.

Authors:  Y Ulgen; M Sezdi
Journal:  Med Biol Eng Comput       Date:  2007-06-28       Impact factor: 2.602

3.  Does obesity affect the non-invasive measurement of cardiac output performed by electrical cardiometry in children and adolescents?

Authors:  Luis Altamirano-Diaz; Eva Welisch; Ralf Rauch; Michael Miller; Teresa Sohee Park; Kambiz Norozi
Journal:  J Clin Monit Comput       Date:  2017-02-17       Impact factor: 2.502

4.  Hereditary spherocytosis and elliptocytosis associated with prosthetic heart valve replacement: rheological study of erythrocyte modifications.

Authors:  Patrizia Caprari; Anna Tarzia; Giorgio Mojoli; Paolo Cianciulli; Emilio Mannella; Maria Cristina Martorana
Journal:  Int J Hematol       Date:  2009-03-24       Impact factor: 2.490

5.  Electrode Positioning to Investigate the Changes of the Thoracic Bioimpedance Caused by Aortic Dissection - A Simulation Study.

Authors:  V Badeli; G M Melito; A Reinbacher-Köstinger; O Bíró; K Ellermann
Journal:  J Electr Bioimpedance       Date:  2020-06-25

6.  Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment.

Authors:  Mugeb Al-Harosh; Marat Yangirov; Dmitry Kolesnikov; Sergey Shchukin
Journal:  Sensors (Basel)       Date:  2021-12-17       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.