Literature DB >> 10371780

[Relationships between air conditioning, airborne microorganisms and health].

S Parat1, A Perdrix, P Baconnier.   

Abstract

Concurrently with the increase of air-conditioning, potentially severe or frequent new diseases have emerged, giving rise to social and economical consequences. The first part of this work is a state of the art review of the relationships between air-conditioning, airborne microorganisms and health, through a technical, metrological and medical approach. The second part presents four studies performed in this field. Two of them deal with the relationship between airborne microorganisms and technical features of air-conditioning. Measurements performed on actual sites demonstrated the benefit of using high efficiency filters and low risk components in air-conditioning systems. The third study was aimed to look for a relationship between airborne microorganisms and sick building syndrome symptoms. Statistical analyses of individual data revealed significant associations between airborne bacteria or fungi and symptoms. These results may be the first step in determining a dose-response relationship, in order to define threshold limit values in this field. In the fourth study, the contribution of particle counting in assessing exposure to airborne microorganisms was explored by monitoring simultaneous variations of microbial and particle concentrations. The results showed that associating particle counting may allow to detect microbial variations instantaneously, and therefore improve the assessment of exposure to airborne microorganisms.

Mesh:

Year:  1999        PMID: 10371780

Source DB:  PubMed          Journal:  Bull Acad Natl Med        ISSN: 0001-4079            Impact factor:   0.144


  3 in total

1.  Bacteria spectra obtained by laser induced fluorescence.

Authors:  Susana Cabredo; Alejandro Parra; Jesús Anzano
Journal:  J Fluoresc       Date:  2007-01-31       Impact factor: 2.217

2.  Two years of a fungal aerobiocontamination survey in a Florentine haematology ward.

Authors:  Gabriella Pini; Rosa Donato; Elisabetta Faggi; Rosa Fanci
Journal:  Eur J Epidemiol       Date:  2004       Impact factor: 8.082

3.  Actual measurement, hygrothermal response experiment and growth prediction analysis of microbial contamination of central air conditioning system in Dalian, China.

Authors:  Yang Lv; Guangyao Hu; Chunyang Wang; Wenjie Yuan; Shanshan Wei; Jiaoqi Gao; Boyuan Wang; Fangchao Song
Journal:  Sci Rep       Date:  2017-04-03       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.