Literature DB >> 10371441

Perfusion imaging using FAIR with a short predelay.

J Zhou1, P C van Zijl.   

Abstract

It is shown theoretically that the flow-sensitive alternating inversion recovery (FAIR) signal intensity difference for flow quantification is independent of the length of the predelay between repeated measurements when assuming complete labeling in between scans. Theory also predicts that flows quantified using the concomitant T1 difference increase significantly with decreasing predelay, because the biexponential relaxation behavior after nonselective inversion is fitted as a monoexponential. The new equations include the effect of the unequal relaxation times of water in tissue (T1) and arterial blood (T1a). While this effect is significant for the signal-difference approach, it is negligible for the T1-difference procedure when using maximum inversion-recovery times shorter than 4 sec. Experiments on cat brain using the FAIR excluding radiation damping (FAIRER) pulse sequence at three different predelays (0.8, 2, and 5 sec) confirm the theoretical predictions.

Entities:  

Mesh:

Year:  1999        PMID: 10371441     DOI: 10.1002/(sici)1522-2594(199906)41:6<1099::aid-mrm5>3.0.co;2-g

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Temporal course of perfusion in human masseter muscle during isometric contraction assessed by arterial spin labeling at 3T.

Authors:  Christina Schraml; Nina F Schwenzer; Petros Martirosian; Claus D Claussen; Fritz Schick
Journal:  MAGMA       Date:  2011-05-15       Impact factor: 2.310

2.  Hemodynamic Responses of the Placenta and Brain to Maternal Hyperoxia in Fetuses with Congenital Heart Disease by Using Blood Oxygen-Level Dependent MRI.

Authors:  Wonsang You; Nickie N Andescavage; Kushal Kapse; Mary T Donofrio; Marni Jacobs; Catherine Limperopoulos
Journal:  Radiology       Date:  2019-11-05       Impact factor: 11.105

3.  Radiation damping in modern NMR experiments: progress and challenges.

Authors:  V V Krishnan; Nagarajan Murali
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2012-06-15       Impact factor: 9.795

4.  Resting myocardial perfusion quantification with CMR arterial spin labeling at 1.5 T and 3.0 T.

Authors:  Benjamin E Northrup; Kyle S McCommis; Haosen Zhang; Shuddhadeb Ray; Pamela K Woodard; Robert J Gropler; Jie Zheng
Journal:  J Cardiovasc Magn Reson       Date:  2008-11-17       Impact factor: 5.364

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.