Literature DB >> 10370078

The isolated working mouse heart: methodological considerations.

T S Larsen1, D D Belke, R Sas, W R Giles, D L Severson, G D Lopaschuk, J V Tyberg.   

Abstract

Our aim was to develop a working isolated murine heart model, as the extensive use of genetically engineered mice in cardiovascular research requires development of new miniaturized technology. Left ventricular (LV) function was assessed in the isolated working mouse heart perfused with recirculated oxygenated Krebs-Henseleit bicarbonate buffer (37 degrees C pH 7.4) containing 11.1 mM glucose and 0.4 mM palmitate bound to 3% albumin. The hearts worked against an afterload reservoir at a height equivalent to 50 mmHg, and heart rate was controlled by electrical pacing of the right atrium. LV pressure was measured with a micromanometer connected to a small steel cannula inserted through the apex of the heart. The experimental protocol consisted of two interventions. First, following instrumentation and stabilization, the preload reservoir was raised from a pressure equivalent of 7 to 22.5 mmHg, while pacing at 390 beats.min-1. Thereafter the height of the preload reservoir was set to 10 mmHg, and the pacing rate was varied from 260 to 600 beats.min-1. Aortic and coronary flows were measured by timed collections of effluent from the afterload line and that dripping from the heart, respectively [aortic+coronary flow=cardiac output (CO)]. Elevation of LV end-diastolic pressure (LVEDP) from approximately 5 to 10 mmHg resulted in a twofold increase in average cardiac power [product of LV developed pressure (LVDevP) and CO], whereas myocardial contractility (first derivative of LV pressure, dP/dt) and LVDevP (LV systolic pressure-LVEDP) increased only minimally (5-10%). Measured LVEDP was lower than the equivalent height of the preload reservoir by an amount that was related to the heart rate. Cardiac power, LVDevP and dP/dt were stable at heart rates up to 400 beats.min-1, but declined markedly with higher rates, consistent with the decrease in LVEDP. Thus, cardiac power was reduced to 50% of its maximum value when stimulated at approximately 500 beats.min-1, and at even higher rates there was little ejection. By systematic manipulation of the height of the preload reservoir and heart rate, we conclude that LV afterload and preload can be assessed only by high-fidelity measurement of intraventricular pressures. The heights of the afterload column and the preload reservoir are unreliable and potentially misleading indicators of LV afterload and preload.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10370078     DOI: 10.1007/s004240050870

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  15 in total

Review 1.  Practical guidelines for rigor and reproducibility in preclinical and clinical studies on cardioprotection.

Authors:  Hans Erik Bøtker; Derek Hausenloy; Ioanna Andreadou; Salvatore Antonucci; Kerstin Boengler; Sean M Davidson; Soni Deshwal; Yvan Devaux; Fabio Di Lisa; Moises Di Sante; Panagiotis Efentakis; Saveria Femminò; David García-Dorado; Zoltán Giricz; Borja Ibanez; Efstathios Iliodromitis; Nina Kaludercic; Petra Kleinbongard; Markus Neuhäuser; Michel Ovize; Pasquale Pagliaro; Michael Rahbek-Schmidt; Marisol Ruiz-Meana; Klaus-Dieter Schlüter; Rainer Schulz; Andreas Skyschally; Catherine Wilder; Derek M Yellon; Peter Ferdinandy; Gerd Heusch
Journal:  Basic Res Cardiol       Date:  2018-08-17       Impact factor: 17.165

2.  Ablation of LKB1 in the heart leads to energy deprivation and impaired cardiac function.

Authors:  Niels Jessen; Ho-Jin Koh; Clifford D Folmes; Cory Wagg; Nobuharu Fujii; Bo Løfgren; Cordula M Wolf; Charles I Berul; Michael F Hirshman; Gary D Lopaschuk; Laurie J Goodyear
Journal:  Biochim Biophys Acta       Date:  2010-05-02

3.  Assessment of Cardiac Morphological and Functional Changes in Mouse Model of Transverse Aortic Constriction by Echocardiographic Imaging.

Authors:  Lei Li; Xiaoyun Guo; Yi Chen; Haifeng Yin; Jing Li; Jessica Doan; Qinghang Liu
Journal:  J Vis Exp       Date:  2016-06-21       Impact factor: 1.355

4.  Aldose Reductase Acts as a Selective Derepressor of PPARγ and the Retinoic Acid Receptor.

Authors:  Devi Thiagarajan; Radha Ananthakrishnan; Jinghua Zhang; Karen M O'Shea; Nosirudeen Quadri; Qing Li; Kelli Sas; Xiao Jing; Rosa Rosario; Subramaniam Pennathur; Ann Marie Schmidt; Ravichandran Ramasamy
Journal:  Cell Rep       Date:  2016-03-24       Impact factor: 9.423

Review 5.  The continuing evolution of the Langendorff and ejecting murine heart: new advances in cardiac phenotyping.

Authors:  Ronglih Liao; Bruno K Podesser; Chee Chew Lim
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-05-25       Impact factor: 4.733

6.  Transthoracic echocardiography in mice.

Authors:  Jonathan L Respress; Xander H T Wehrens
Journal:  J Vis Exp       Date:  2010-05-28       Impact factor: 1.355

7.  ATP splitting by half the cross-bridges can explain the twitch energetics of mouse papillary muscle.

Authors:  C Widén; C J Barclay
Journal:  J Physiol       Date:  2006-02-23       Impact factor: 5.182

8.  Cardioselective dominant-negative thyroid hormone receptor (Delta337T) modulates myocardial metabolism and contractile efficiency.

Authors:  Outi M Hyyti; Aaron K Olson; Ming Ge; Xue-Han Ning; Norman E Buroker; Youngran Chung; Thomas Jue; Michael A Portman
Journal:  Am J Physiol Endocrinol Metab       Date:  2008-06-03       Impact factor: 4.310

9.  A protocol to study ex vivo mouse working heart at human-like heart rate.

Authors:  Han-Zhong Feng; Jian-Ping Jin
Journal:  J Mol Cell Cardiol       Date:  2017-11-17       Impact factor: 5.000

10.  Changes in substrate metabolism in isolated mouse hearts following ischemia-reperfusion.

Authors:  Ellen Aasum; Anne D Hafstad; Terje S Larsen
Journal:  Mol Cell Biochem       Date:  2003-07       Impact factor: 3.396

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.