Literature DB >> 10369943

Automatic segmentation of dynamic neuroreceptor single-photon emission tomography images using fuzzy clustering.

P D Acton1, L S Pilowsky, H F Kung, P J Ell.   

Abstract

The segmentation of medical images is one of the most important steps in the analysis and quantification of imaging data. However, partial volume artefacts make accurate tissue boundary definition difficult, particularly for images with lower resolution commonly used in nuclear medicine. In single-photon emission tomography (SPET) neuroreceptor studies, areas of specific binding are usually delineated by manually drawing regions of interest (ROIs), a time-consuming and subjective process. This paper applies the technique of fuzzy c-means clustering (FCM) to automatically segment dynamic neuroreceptor SPET images. Fuzzy clustering was tested using a realistic, computer-generated, dynamic SPET phantom derived from segmenting an MR image of an anthropomorphic brain phantom. Also, the utility of applying FCM to real clinical data was assessed by comparison against conventional ROI analysis of iodine-123 iodobenzamide (IBZM) binding to dopamine D2/D3 receptors in the brains of humans. In addition, a further test of the methodology was assessed by applying FCM segmentation to [123I]IDAM images (5-iodo-2-[[2-2-[(dimethylamino)methyl]phenyl]thio] benzyl alcohol) of serotonin transporters in non-human primates. In the simulated dynamic SPET phantom, over a wide range of counts and ratios of specific binding to background, FCM correlated very strongly with the true counts (correlation coefficient r2>0.99, P<0.0001). Similarly, FCM gave segmentation of the [123I]IBZM data comparable with manual ROI analysis, with the binding ratios derived from both methods significantly correlated (r2=0.83, P<0.0001). Fuzzy clustering is a powerful tool for the automatic, unsupervised segmentation of dynamic neuroreceptor SPET images. Where other automated techniques fail completely, and manual ROI definition would be highly subjective, FCM is capable of segmenting noisy images in a robust and repeatable manner.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10369943     DOI: 10.1007/s002590050425

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  4 in total

Review 1.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

2.  Automatic semi-quantification of [123I]FP-CIT SPECT scans in healthy volunteers using BasGan version 2: results from the ENC-DAT database.

Authors:  Flavio Nobili; Mehrdad Naseri; Fabrizio De Carli; Susan Asenbaum; Jan Booij; Jacques Darcourt; Peter Ell; Ozlem Kapucu; Paul Kemp; Claus Svarer; Claus Varer; Silvia Morbelli; Marco Pagani; Osama Sabri; Klaus Tatsch; Livia Tossici-Bolt; Terez Sera; Tierry Vander Borght; Koen Van Laere; Andrea Varrone
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-12-12       Impact factor: 9.236

3.  IBZM tool: a fully automated expert system for the evaluation of IBZM SPECT studies.

Authors:  Ralph Buchert; Georg Berding; Florian Wilke; Brigitte Martin; Daniel von Borczyskowski; Janos Mester; Winfried Brenner; Malte Clausen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-14       Impact factor: 9.236

4.  The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation.

Authors:  Piero Calvini; Guido Rodriguez; Fabrizio Inguglia; Alessandro Mignone; Ugo Paolo Guerra; Flavio Nobili
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-08       Impact factor: 10.057

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.