The application of turbidimetric homogeneous immunoassays made the determination of several plasma components widely available. The sensitivity and accuracy of these assays are appropriate enough for routine laboratory use; however, in the case of many pathologically high concentration samples, prozone effect (high dose hook effect) can be observed, that leads to false-negative determination. Up to the present there are no cost-effective algorithms available for the safe detection of the prozone effect. Pathological serum ferritin values can be elevated up to 5000 ng/ml, while the measuring range covers only the 0-440 ng/ml range by a commercial assay. The determination of samples with ferritin concentration higher than 1500 ng/ml results in false-negative values because of the overlapping measuring range and prozone effect range. The prozone effect can be recognised by analysis of reaction kinetics after measurement. We have developed a neural network classifier system to analyse reaction kinetics of the measurements and check the prozone effect. One thousand five hundred determinations and 77 patient samples were used for neural network training and test. Using the trained neural networks, false-negative results can be filtered immediately after the determination, without re-run; thus, the sensitivity of plasma ferritin determination may become reliable enough, even in the case of high concentration samples. Applying this new technology, false-negative serum ferritin determinations can be avoided, thus even a relatively high hook effect rate (5-12% in different patient groups) can be handled safely.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10369120     DOI: 10.1515/CCLM.1999.076

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  3 in total

1.  Giant invasive pituitary prolactinoma with falsely low serum prolactin: the significance of 'hook effect'.

Authors:  Maria Fleseriu; Michael Lee; Maria M Pineyro; Mario Skugor; Sethu K Reddy; Elias S Siraj; Amir H Hamrahian
Journal:  J Neurooncol       Date:  2006-04-06       Impact factor: 4.130

2.  Laboratory demonstration of a prozone-like effect in HRP2-detecting malaria rapid diagnostic tests: implications for clinical management.

Authors:  Jennifer Luchavez; Joanne Baker; Sheila Alcantara; Vicente Belizario; Qin Cheng; James S McCarthy; David Bell
Journal:  Malar J       Date:  2011-09-29       Impact factor: 2.979

3.  Upfront dilution of ferritin samples to reduce hook effect, improve turnaround time and reduce costs.

Authors:  Shu Juan Wu; Joshua A Hayden
Journal:  Biochem Med (Zagreb)       Date:  2017-11-24       Impact factor: 2.313

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.