Literature DB >> 10367875

Image-guided surgery: preliminary feasibility studies of frameless stereotactic liver surgery.

A J Herline1, J D Stefansic, J P Debelak, S L Hartmann, C W Pinson, R L Galloway, W C Chapman.   

Abstract

BACKGROUND: Liver surgery can be difficult because there are few external landmarks defining hepatic anatomy and because the liver has significant vascularity. Although preoperative tomographic imaging (computed tomography or magnetic resonance imaging) provides essential anatomical information for operative planning, at present it cannot be used actively for precise localization during surgery. Interactive image-guided surgery involves the simultaneous real-time display of intraoperative instrument location on preoperative images (computed or positron-emission tomography or magnetic resonance imaging). Interactive image-guided surgery has been described for tumor localization in the brain (frameless stereotactic surgery) and allows for interactive use of preoperative images during resections or biopsies. HYPOTHESIS: The application of interactive image-guided surgery (IIGS) is feasible for hepatic procedures from a biomedical engineering standpoint.
METHODS: We developed an interactive image-guided surgery system for liver surgery and tested a porcine liver model for tracking liver motion during insufflation; liver motion during respiration in open procedures in patients undergoing hepatic resection; and tracking accuracy of general surgical instruments, including a laparoscope and an ultrasound probe.
RESULTS: Liver motion due to insufflation can be quantified; average motion was 2.5+/-1.4 mm. Average total liver motion secondary to respiration in patients was 10.8 +/-2.5 mm. Instruments of varying lengths, including a laparoscope, can be tracked to accuracies ranging from 1.4 to 2.1 mm within a 27-m3 (3 X 3 X 3-m) space.
CONCLUSION: Interactive image-guided surgery appears to be feasible for open and laparoscopic hepatic procedures and may enhance future operative localization.

Entities:  

Mesh:

Year:  1999        PMID: 10367875     DOI: 10.1001/archsurg.134.6.644

Source DB:  PubMed          Journal:  Arch Surg        ISSN: 0004-0010


  16 in total

1.  Novel 3-D laparoscopic magnetic ultrasound image guidance for lesion targeting.

Authors:  David Sindram; Iain H McKillop; John B Martinie; David A Iannitti
Journal:  HPB (Oxford)       Date:  2010-12       Impact factor: 3.647

2.  A clinically applicable laser-based image-guided system for laparoscopic liver procedures.

Authors:  Matteo Fusaglia; Hanspeter Hess; Marius Schwalbe; Matthias Peterhans; Pascale Tinguely; Stefan Weber; Huanxiang Lu
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-17       Impact factor: 2.924

3.  Ultrasound-to-computer-tomography registration for image-guided laparoscopic liver surgery.

Authors:  P Bao; J Warmath; R Galloway; A Herline
Journal:  Surg Endosc       Date:  2005-01-10       Impact factor: 4.584

4.  Concepts and preliminary data toward the realization of image-guided liver surgery.

Authors:  David M Cash; Michael I Miga; Sean C Glasgow; Benoit M Dawant; Logan W Clements; Zhujiang Cao; Robert L Galloway; William C Chapman
Journal:  J Gastrointest Surg       Date:  2007-07       Impact factor: 3.452

5.  Robust surface registration using salient anatomical features for image-guided liver surgery: algorithm and validation.

Authors:  Logan W Clements; William C Chapman; Benoit M Dawant; Robert L Galloway; Michael I Miga
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

6.  Image-guided real-time navigation for transanal total mesorectal excision: a pilot study.

Authors:  S Atallah; B Martin-Perez; S Larach
Journal:  Tech Coloproctol       Date:  2015-07-09       Impact factor: 3.781

7.  Projective biomechanical depth matching for soft tissue registration in laparoscopic surgery.

Authors:  Daniel Reichard; Dominik Häntsch; Sebastian Bodenstedt; Stefan Suwelack; Martin Wagner; Hannes Kenngott; Beat Müller-Stich; Lena Maier-Hein; Rüdiger Dillmann; Stefanie Speidel
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-05-26       Impact factor: 2.924

Review 8.  [Navigated liver surgery : Current state and importance in the future].

Authors:  K J Oldhafer; M Peterhans; A Kantas; A Schenk; G Makridis; S Pelzl; K C Wagner; S Weber; G A Stavrou; M Donati
Journal:  Chirurg       Date:  2018-10       Impact factor: 0.955

9.  Laparoscopic image-based navigation for microwave ablation of liver tumors-A multi-center study.

Authors:  Pascale Tinguely; Matteo Fusaglia; Jacob Freedman; Vanessa Banz; Stefan Weber; Daniel Candinas; Henrik Nilsson
Journal:  Surg Endosc       Date:  2017-03-24       Impact factor: 4.584

10.  Current Evidence in Image-Guided Liver Surgery.

Authors:  Amber L Simpson; T Peter Kingham
Journal:  J Gastrointest Surg       Date:  2016-03-08       Impact factor: 3.452