Literature DB >> 10367835

A new temporary catheter (ContiCath) for the treatment of temporary, reversible, postoperative urinary retention.

M Corujo1, G H Badlani, J B Regan, J H Lynch, K Tomera, R Schmidt, C Calvosa, E Ramsey, D J Lightner, D M Barrett.   

Abstract

OBJECTIVES: To describe the initial experience of a newly designed temporary urethral catheter, ContiCath, as an aid in the management of postoperative or temporary outflow obstruction. In patients with normal detrusor and sphincter function, this catheter allows volitional voiding while maintaining an open prostatic urethra.
METHODS: In a pilot study, 64 nonconsecutive patients with postoperative or temporary urinary retention, at eight clinical trial sites, were enrolled for the placement of this temporary catheter. Three patients did not have the catheter placed because of placement failure because of either a large median lobe or a urethral stricture. The remaining 61 patients were divided into three groups: those with non-neuropathic causes of retention and retention for 1 week or less (37 patients), those with non-neuropathic causes of retention and retention for longer than 1 week (19 patients), and those with neuropathic causes of retention and retention for longer than 1 week (5 patients). The ContiCath is placed in the office setting, in the same fashion as a Foley catheter. A blue prolene tether extends from the bulbar urethra to the meatus to assist in the removal of the device. Patients were then reassessed at 3 hours, and at 7, 14, 21, and 28 days, at which point the device was removed.
RESULTS: In patients with a neuropathic cause for their retention (5 patients) and those with non-neuropathic causes of retention and retention for longer than 1 week (19 patients), only 3 patients were able to void after the catheter was placed. Of the 37 patients with a non-neuropathic cause and retention 1 week or less, controlled voiding was seen in 33 patients (89%). Controlled voiding was defined as the patient's volitional ability to initiate and stop his urinary stream. There were no complications with catheter placement; however, 8 patients (24.2%) had minor adverse experiences of frequency/urgency (n = 3), incontinence (n = 3), migration of the catheter (n = 1), and pain (n = 1).
CONCLUSIONS: ContiCath offers an alternative to an indwelling Foley catheter in men with temporary bladder outlet obstruction and urinary retention.

Entities:  

Mesh:

Year:  1999        PMID: 10367835     DOI: 10.1016/s0090-4295(99)00058-8

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  2 in total

1.  Spinal hyperexcitability and bladder hyperreflexia during reversible frontal cortical inactivation induced by low-frequency electrical stimulation in the cat.

Authors:  Victor Pikov; Douglas B McCreery
Journal:  J Neurotrauma       Date:  2009-01       Impact factor: 5.269

2.  Critical appraisal of the Spanner™ prostatic stent in the treatment of prostatic obstruction.

Authors:  Patrick McKenzie; Gopal Badlani
Journal:  Med Devices (Auckl)       Date:  2011-02-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.