P Endt1, H D Hahlbohm, D Kreiseler, M Oeff, U Steinhoff, L Trahms.
Abstract
The structure of high-frequency components of electric and magnetic signals from the heart during the depolarisation phase is investigated. After averaging and broadband filtering with a binomial bandpass filter (37 Hz-90 Hz), the fragmentation of the QRS-complex is quantified. The number of extrema M and a new score value S are calculated from the signals of three electrical leads and one magnetic lead of 23 healthy subjects, 23 patients with coronary heart disease (CHD) without reported event of ventricular tachycardia or fibrillation at the time of measurement, and eight patients with CHD who have suffered from malignant tachycardia. For the parameter M, the sensitivity and specificity for healthy subjects against patients with CHD and ventricular tachycardia for the magnetic lead (the best electric lead) are 100% (75%) and 100% (100%). For the magnetic lead (best electric lead) and parameter S, the sensitivity and specificity are 100% (75%) and 95.6% (100%).Entities:
Mesh:
Year: 1998 PMID: 10367463 DOI: 10.1007/bf02518875
Source DB: PubMed Journal: Med Biol Eng Comput ISSN: 0140-0118 Impact factor: 2.602