Literature DB >> 10367448

Quantification of the morphological features of a full microvascular network.

S B Bidiwala1, M S Mansour, C K Stengel, S A Klein, S M Carroll, S C Koenig, A H Desoky, G R Tobin, C Maldonado, J H Barker.   

Abstract

Investigations into the changes that occur in microvasculature following the surgical procedure called delay have brought about the need for a computer system capable of quantifying the morphological features of a full microvascular network in terms of average vessel length, diameter, and tortuosity. Both the formulaic conventions that have been developed to measure these quantities as well as their implementation in the form of a HP-9000/UNIX based computer software system that we developed specifically for this purpose are discussed. Reliability studies performed using the final system to measure the microcirculatory network of a mouse latissmus dorsi muscle (LDM) showed 95% confidence intervals within 5% of means and coefficients of variability within 7% of means for all quantities measured in large (150-300 microns), medium (50-150 microns), and small (< 50 microns) diameter vessels. These variations were significantly smaller than the changes that were observed in a preliminary study comparing these microvascular network parameters before and after delay in the hairless mouse LDM, showing the proposed quantification methods to be well suited to the study of the microvascular changes following delay. It is hoped that the formulaic conventions, implementation process and reliability data will provide a useful comparison for other researchers interested in measuring similar features of microcirculatory networks.

Entities:  

Mesh:

Year:  1998        PMID: 10367448     DOI: 10.1007/bf02524434

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  14 in total

1.  Vascular patterns and active vasomotion as determiners of flow through minute vessels.

Authors:  P A NICOLL; R L WEBB
Journal:  Angiology       Date:  1955-08       Impact factor: 3.619

2.  Direct monitoring of nutritive blood flow in a failing skin flap: the hairless mouse ear skin-flap model.

Authors:  J H Barker; F Hammersen; I Bondàr; T J Galla; M D Menger; W Gross; K Messmer
Journal:  Plast Reconstr Surg       Date:  1989-08       Impact factor: 4.730

3.  The Blood-Pressure and its Variations in the Arterioles, Capillaries and Smaller Veins.

Authors:  C S Roy; J G Brown
Journal:  J Physiol       Date:  1880-07       Impact factor: 5.182

4.  Coincident bit counting-a new criterion for image registration.

Authors:  J Y Chiang; B J Sullivan
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

5.  The pathophysiology of skin flap circulation. The delay phenomenon.

Authors:  J F Reinisch
Journal:  Plast Reconstr Surg       Date:  1974-11       Impact factor: 4.730

6.  Microvascular measurements by video image shearing and splitting.

Authors:  M Intaglietta; W R Tompkins
Journal:  Microvasc Res       Date:  1973-05       Impact factor: 3.514

7.  Influence of flow variations on capillary hematocrit in mesentery.

Authors:  P C Johnson; J Blaschke; K S Burton; J H Dial
Journal:  Am J Physiol       Date:  1971-07

8.  Analysis of network flow distribution: computational aid to minimize experimental expenditure.

Authors:  T Wetter; D Hoffmann; H Schmid-Schönbein
Journal:  Microvasc Res       Date:  1983-09       Impact factor: 3.514

9.  Postmortem changes in stereological parameters of cerebral capillaries.

Authors:  O Hunziker; A Schweizer
Journal:  Beitr Pathol       Date:  1977-11

10.  Vascular delay in skeletal muscle: a model for microcirculatory studies.

Authors:  J H Barker; V C van Aalst; P C Keelen; S Bidiwala; J M Frank; S M Carroll; C Wan; C M Carroll; G L Anderson; C Joels; G R Tobin
Journal:  Plast Reconstr Surg       Date:  1997-09       Impact factor: 4.730

View more
  2 in total

1.  Quantitative analysis of vascular parameters for micro-CT imaging of vascular networks with multi-resolution.

Authors:  Fengjun Zhao; Jimin Liang; Xueli Chen; Junting Liu; Dongmei Chen; Xiang Yang; Jie Tian
Journal:  Med Biol Eng Comput       Date:  2015-06-25       Impact factor: 2.602

2.  Three-dimensional analysis of tumour vascular corrosion casts using stereoimaging and micro-computed tomography.

Authors:  A A Folarin; M A Konerding; J Timonen; S Nagl; R B Pedley
Journal:  Microvasc Res       Date:  2010-03-19       Impact factor: 3.514

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.