Literature DB >> 10366995

Validation and use of the CALUX-bioassay for the determination of dioxins and PCBs in bovine milk.

T F Bovee1, L A Hoogenboom, A R Hamers, W A Traag, T Zuidema, J M Aarts, A Brouwer, H A Kuiper.   

Abstract

There is a strong need for the development of relatively cheap and rapid bioassays for the determination of dioxins and related compounds in food. A newly developed CALUX (Chemical-Activated LUciferase gene eXpression) bioassay was tested for its possible use to determine low levels of dioxins in bovine milk. Data show that this mammalian cell-based test is very sensitive for 2,3,7,8-substituted dioxins and related PCBs, thereby reflecting the relative potencies of these compounds in comparison to TCDD (TEF-values). The limit of detection was about 50 fg of TCDD. Furthermore, the response obtained with a mixture of dioxins was additive, in accordance with the TEF-principle. Milk fat was isolated by centrifugation followed by clean-up of the fat with n-pentane, removal of the fat on a 33% H2SO4 silica column, and determination of Ah receptor agonist activity with the CALUX-bioassay. An equivalent of 67 mg fat was tested per experimental unit, resulting in a limit of quantification around 1 pg i-TEQ/g fat. To investigate the performance of the method, butter fat was cleaned and spiked with a mixture of 17 different 2,3,7,8-substituted PCDD and PCDF congeners at 1, 3, 6, 9, 12 and 15 pg TEQ/g fat, as confirmed by GC/MS. In this concentration range, the method showed a recovery of TEQs around 67% (58-87%). The reproducibility, determined in three independent series showed a CV varying between 4% and 54%, with the exception of the sample spiked at 1 pg i-TEQ (CV 97%). The repeatability determined with the sample spiked at 6 pg i-TEQ/g showed a CV of 10%. Testing of 22 bovine milk samples, taken at different sites in The Netherlands, in the CALUX-assay showed combined dioxin and dioxin-like PCB levels equivalent to 1.6 pg TCDD/g fat (range 0.2-4.6). GC/MS analysis of these samples revealed an average level of 1.7 pg i-TEQ/g fat, varying between 0.5 and 4.7 pg i-TEQ/g fat. All five samples showing a GC/MS determined dioxin content of more than 2 pg i-TEQ/g fat gave a response in the CALUX-assay corresponding to more than 2 pg TCDD/g fat. These data clearly show that the CALUX-bioassay is a promising method for the rapid and low cost screening of dioxins in bovine milk.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10366995     DOI: 10.1080/02652039809374723

Source DB:  PubMed          Journal:  Food Addit Contam        ISSN: 0265-203X


  9 in total

Review 1.  The combined use of the CALUX bioassay and the HRGC/HRMS method for the detection of novel dioxin sources and new dioxin-like compounds.

Authors:  Ron Hoogenboom
Journal:  Environ Sci Pollut Res Int       Date:  2002       Impact factor: 4.223

2.  Induction of cytochrome P450 1A by cow milk-based formula: a comparative study between human milk and formula.

Authors:  Haibo Xu; Ratheishan Rajesan; Patricia Harper; Richard B Kim; Bo Lonnerdal; Mingdong Yang; Satoko Uematsu; Janine Hutson; Jo Watson-MacDonell; Shinya Ito
Journal:  Br J Pharmacol       Date:  2005-09       Impact factor: 8.739

3.  A sensitive, rapid, and simple DR-EcoScreen bioassay for the determination of PCDD/Fs and dioxin-like PCBs in environmental and food samples.

Authors:  Hiroyuki Kojima; Shinji Takeuchi; Mitsuru Iida; Shoji F Nakayama; Takuya Shiozaki
Journal:  Environ Sci Pollut Res Int       Date:  2015-06-19       Impact factor: 4.223

Review 4.  Detection of organic compounds with whole-cell bioluminescent bioassays.

Authors:  Tingting Xu; Dan Close; Abby Smartt; Steven Ripp; Gary Sayler
Journal:  Adv Biochem Eng Biotechnol       Date:  2014       Impact factor: 2.635

Review 5.  The need and potential of biosensors to detect dioxins and dioxin-like polychlorinated biphenyls along the milk, eggs and meat food chain.

Authors:  Jeerasak Chobtang; Imke J M de Boer; Ron L A P Hoogenboom; Willem Haasnoot; Aize Kijlstra; Bastiaan G Meerburg
Journal:  Sensors (Basel)       Date:  2011-12-15       Impact factor: 3.576

6.  Comparison of chemical-activated luciferase gene expression bioassay and gas chromatography for PCB determination in human serum and follicular fluid.

Authors:  A Pauwels; P H Cenijn; P J Schepens; A Brouwer
Journal:  Environ Health Perspect       Date:  2000-06       Impact factor: 9.031

7.  Association between DNA methylation profiles in leukocytes and serum levels of persistent organic pollutants in Dutch men.

Authors:  Myrthe W van den Dungen; Albertinka J Murk; Ellen Kampman; Wilma T Steegenga; Dieuwertje E Kok
Journal:  Environ Epigenet       Date:  2017-02-27

Review 8.  Immunoanalysis methods for the detection of dioxins and related chemicals.

Authors:  Wenjing Tian; Heidi Qunhui Xie; Hualing Fu; Xinhui Pei; Bin Zhao
Journal:  Sensors (Basel)       Date:  2012-12-05       Impact factor: 3.576

Review 9.  Analytic considerations for measuring environmental chemicals in breast milk.

Authors:  Larry L Needham; Richard Y Wang
Journal:  Environ Health Perspect       Date:  2002-06       Impact factor: 9.031

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.