Characteristics of pedicle screw loading. Effect of sagittal insertion angle on intrapedicular bending moments.

J A Youssef1, T O McKinley, S A Yerby, R F McLain.   

Abstract

STUDY
DESIGN: A bending analysis of pedicle screws inserted into vertebral body analogues. Intravertebral and intrapedicular pedicle screw bending moments were studied as a function of sagittal insertion angle.
OBJECTIVES: To determine how the pedicle screw bending moment is affected by changes in the insertion angle. SUMMARY OF BACKGROUND DATA: There is a significant incidence of failure when pedicle screws are used to instrument unstable spinal segments. Extrinsic factors that affect screw bending failure have been poorly characterized. Previous work has demonstrated that intrapedicular pedicle screw bending moments are significantly affected by the sagittal location and depth of pedicle screw placement.
METHODS: Pedicle screw transducers were inserted in analogue vertebrae at one of three orientations: 7 degrees cephalad (toward the superior endplate), 7 degrees caudal (toward the inferior endplate), or parallel to the superior endplate (control). An axial load was applied to the superior endplate of the vertebra, and screw bending moments were recorded directly from the transducers.
RESULTS: Screws angled 7 degrees cephalad developed significantly greater mean intrapedicular bending moments compared with screws inserted caudal or control screws. There was no significant difference in bending moments realized within the vertebral body for the three screw positions.
CONCLUSIONS: Angulating pedicle screws toward the superior endplate increased bending moments within the pedicle. If attention to optimal screw insertion technique can reduce bending moments and potential for screw failure without increasing morbidity, surgical risk, or operative time, then proper insertion technique takes on new importance.

Mesh:

Year:  1999        PMID: 10361656     DOI: 10.1097/00007632-199906010-00006

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  3 in total

1.  Effect of screw position on load transfer in lumbar pedicle screws: a non-idealized finite element analysis.

Authors:  Anna G U S Newcomb; Seungwon Baek; Brian P Kelly; Neil R Crawford
Journal:  Comput Methods Biomech Biomed Engin       Date:  2016-07-25       Impact factor: 1.763

2.  Stress distribution of different lumbar posterior pedicle screw insertion techniques: a combination study of finite element analysis and biomechanical test.

Authors:  Mingzhi Song; Kebin Sun; Zhonghai Li; Junwei Zong; Xiliang Tian; Kai Ma; Shouyu Wang
Journal:  Sci Rep       Date:  2021-06-21       Impact factor: 4.379

3.  Finite Element Analysis and Biomechanical Comparison of Short Posterior Spinal Instrumentation with Divergent Bridge Construct versus Parallel Tension Band Construct for Thoracolumbar Spine Fractures.

Authors:  Jean A Ouellet; Corey Richards; Zeeshan M Sardar; Demetri Giannitsios; Nicholas Noiseux; Willem S Strydom; Rudy Reindl; Peter Jarzem; Vincent Arlet; Thomas Steffen
Journal:  Global Spine J       Date:  2013-05-23
  3 in total