Literature DB >> 10358989

Mesh-and-glue technique to prevent leakage of cerebrospinal fluid after implantation of expanded polytetrafluoroethylene dura substitute--technical note.

K Nagata1, S Kawamoto, J Sashida, T Abe, A Mukasa, Y Imaizumi.   

Abstract

Expanded polytetrafluoroethylene (ePTFE) can be used as a dura substitute but is associated with leakage of cerebrospinal fluid (CSF) through the suture line. Fibrin glue alone may not prevent this problem. This new method for sealing the suture line in ePTFE membrane uses an absorbable polyglycoic acid mesh soaked with fibrinogen fluid placed on the suture line. Thrombin fluid is then slowly applied to the wet mesh, forming a large fibrin membrane reinforced by the mesh over the suture line. Only one of 33 patients in whom this technique was used had CSF leakage, whereas 12 of 59 patients in whom a dural defect was closed with ePTFE alone showed postoperative subcutaneous CSF collection (p < 0.05). Our clinical experiences clearly show the efficacy of the mesh-and-glue technique to prevent CSF leakage after artificial dural substitution. Mesh and glue can provide an adequate repair for small dural defect. The mesh-and-glue technique may also be used for arachnoid sealing in spinal surgery.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10358989     DOI: 10.2176/nmc.39.316

Source DB:  PubMed          Journal:  Neurol Med Chir (Tokyo)        ISSN: 0470-8105            Impact factor:   1.742


  1 in total

1.  Posterior Laminoplastic Laminotomy Combined with a Paraspinal Transmuscular Approach for Removing a Lumbar Dumbbell-shaped Schwannoma: A Technical Note.

Authors:  Japhet Gideon Ngerageza; Kiyoshi Ito; Tatsuro Aoyama; Takahiro Murata; Tetsuyoshi Horiuchi; Kazuhiro Hongo
Journal:  Neurol Med Chir (Tokyo)       Date:  2015-09-04       Impact factor: 1.742

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.