Literature DB >> 10351985

Strand displacement amplification and homogeneous real-time detection incorporated in a second-generation DNA probe system, BDProbeTecET.

M C Little1, J Andrews, R Moore, S Bustos, L Jones, C Embres, G Durmowicz, J Harris, D Berger, K Yanson, C Rostkowski, D Yursis, J Price, T Fort, A Walters, M Collis, O Llorin, J Wood, F Failing, C O'Keefe, B Scrivens, B Pope, T Hansen, K Marino, K Williams.   

Abstract

BACKGROUND: Amplified DNA probes provide powerful tools for the detection of infectious diseases, cancer, and genetic diseases. Commercially available amplification systems suffer from low throughput and require decontamination schemes, significant hands-on time, and specially trained laboratory staff. Our objective was to develop a DNA probe system to overcome these limitations.
METHODS: We developed a DNA probe system, the BDProbeTecTMET, based on simultaneous strand displacement amplification and real-time fluorescence detection. The system uses sealed microwells to minimize the release of amplicons to the environment. To avoid the need for specially trained labor, the system uses a simple workflow with predispensed reagent devices; a programmable, expandable-spacing pipettor; and the 96-microwell format. Amplification and detection time was 1 h, with potential throughput up to 564 patient results per shift. We tested 122 total patient specimens obtained from a family practice clinic with the BD ProbeTecET and the Abbott LCx(R) amplified system for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae.
RESULTS: Based on reportable results, the BDProbeTecET results for both organisms were 100% sensitive and 100% specific relative to the LCx.
CONCLUSIONS: The BDProbeTecET is an easy-to-use, high-throughput, closed amplification system for the detection of nucleic acid from C. trachomatis and N. gonorrhoeae and other organisms.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10351985

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  30 in total

1.  Evaluation of the BDProbeTec ET system for direct detection of Mycobacterium tuberculosis in pulmonary and extrapulmonary samples: a multicenter study.

Authors:  Gianna Mazzarelli; Laura Rindi; Paola Piccoli; Claudio Scarparo; Carlo Garzelli; Enrico Tortoli
Journal:  J Clin Microbiol       Date:  2003-04       Impact factor: 5.948

2.  Clinical evaluation of the BDProbeTec ET system for rapid detection of Mycobacterium tuberculosis.

Authors:  J S Bergmann; W E Keating; G L Woods
Journal:  J Clin Microbiol       Date:  2000-02       Impact factor: 5.948

3.  Comparison of the BDProbeTec ET system with the Cobas Amplicor PCR for direct detection of Mycobacterium tuberculosis in respiratory samples.

Authors:  Y Iinuma; K Senda; N Fujihara; T Saito; S Takakura; M Shimojima; T Kudo; S Ichiyama
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2003-05-16       Impact factor: 3.267

4.  Detection of Chlamydia trachomatis and Neisseria gonorrhoeae by strand displacement amplification and relevance of the amplification control for use with vaginal swab specimens.

Authors:  Lisa A Cosentino; Daniel V Landers; Sharon L Hillier
Journal:  J Clin Microbiol       Date:  2003-08       Impact factor: 5.948

Review 5.  Nucleic acid amplification testing for Neisseria gonorrhoeae: an ongoing challenge.

Authors:  David M Whiley; John W Tapsall; Theo P Sloots
Journal:  J Mol Diagn       Date:  2006-02       Impact factor: 5.568

6.  Impact of a chemistry-based DNA extraction method on performance of a commercial amplification assay for detection of Mycobacterium tuberculosis complex.

Authors:  Claudio Piersimoni; Giancarlo Gherardi; Domenico Nista; Stefano Bornigia
Journal:  J Clin Microbiol       Date:  2008-11-19       Impact factor: 5.948

7.  Evaluation of six commercial nucleic acid amplification tests for detection of Neisseria gonorrhoeae and other Neisseria species.

Authors:  Sepehr N Tabrizi; Magnus Unemo; Athena E Limnios; Tiffany R Hogan; Stig-Ove Hjelmevoll; Susanne M Garland; John Tapsall
Journal:  J Clin Microbiol       Date:  2011-08-03       Impact factor: 5.948

8.  Comparison between DiaPlexQ™ STI6 and GeneFinder™ STD I/STD II multiplex Real-time PCR Kits in the detection of six sexually transmitted disease pathogens.

Authors:  Hee Jae Huh; Chang-Seok Ki; Sun Ae Yun; Jungsoo Lee; Gwi Young Oh; Nam-Sihk Lee; Young Ho Yoon; Nam Yong Lee
Journal:  J Clin Lab Anal       Date:  2018-11-02       Impact factor: 2.352

9.  Performance assessment of two commercial amplification assays for direct detection of Mycobacterium tuberculosis complex from respiratory and extrapulmonary specimens.

Authors:  Claudio Piersimoni; Claudio Scarparo; Paola Piccoli; Alessandra Rigon; Giuliana Ruggiero; Domenico Nista; Stefano Bornigia
Journal:  J Clin Microbiol       Date:  2002-11       Impact factor: 5.948

Review 10.  Diagnosis and assessment of trachoma.

Authors:  Anthony W Solomon; Rosanna W Peeling; Allen Foster; David C W Mabey
Journal:  Clin Microbiol Rev       Date:  2004-10       Impact factor: 26.132

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.