The influence of transmural pressure and longitudinal stretch on K+- and Ca2+-induced coronary artery constriction.

O Frøbert1, E O Mikkelsen, J P Bagger.   

Abstract

UNLABELLED: The aim of the study was to investigate transmural pressure and longitudinal stretch modulation of K+- and Ca2+-induced constriction of porcine conductance coronary arteries. In a pressure myograph set-up, left anterior descendent coronary arteries from 70 to 90 kg pigs were investigated at pressures from 20 to 120 mmHg. Longitudinal extension ratio (lambda = L/L0(-1), where L0 is the in situ length and L the examination length) varied between 0.9 and 1.1. Two protocols were carried out: (1) Outer diameter response to maximal depolarization by K+ 125 mM at 20-120 mmHg and lambda at 0.90-1.10. (2) Concentration-response curves with K+ (4.7-125 mM) and Ca2+ (0.05-4.0 mM) at four combinations of P and lambda (P = 100 mmHg, lambda = 0.9; P = 100 mmHg, lambda = 1.1; P = 40 mmHg, lambda = 0.9; p = 40 mmHg, lambda = 1.1).
RESULTS: Endothelial function was preserved. A slight (<5% diameter reduction) basal tone and no myogenic response was found. Protocol 1: the constriction to K+ 125 mM was maximal in a wide pressure range from 40 to 120 mmHg. Despite the fact that K+-induced diameter changes were statistically insignificant between 40 and 120 mmHg, there was a linear trend towards smaller diameter changes in this pressure range (r = -0.54, P < 0.01). Stretch influenced constriction at 20 mmHg because lambda = 0.90 and 0.95 resulted in smaller diameter-reductions than lambda = 1.00-1.10 (P < 0.05 for all). Contrastingly, at 120 mmHg the constriction at lambda = 1.10 was smaller than the responses at lambda = 0.90-1.05 (P < 0.05 for all). Protocol 2: EC50 and EC10 values for K+- and Ca2+ were generally higher (more sensitive) at 40 compared with 100 mmHg. Stretch was of no significant importance for EC50 and EC10 at 40 and 100 mmHg. It is concluded that porcine coronary artery constriction to non-metabolized agonists is maximal at 40 mmHg with a trend towards smaller diameter changes with higher pressures. Longitudinal stretch affects responsiveness at pressure extremes.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10350232     DOI: 10.1046/j.1365-201x.1999.00519.x

Source DB:  PubMed          Journal:  Acta Physiol Scand        ISSN: 0001-6772


  6 in total

1.  Transmural pressure and axial loading interactively regulate arterial remodeling ex vivo.

Authors:  Amanda R Lawrence; Keith J Gooch
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-05-22       Impact factor: 4.733

2.  Adenosine concentration in the porcine coronary artery wall and A2A receptor involvement in hypoxia-induced vasodilatation.

Authors:  Ole Frøbert; Gesine Haink; Ulf Simonsen; Claus H Gravholt; Max Levin; Andreas Deussen
Journal:  J Physiol       Date:  2005-11-10       Impact factor: 5.182

3.  Measurement of interstitial lactate during hypoxia-induced dilatation in isolated pressurised porcine coronary arteries.

Authors:  Ole Frøbert; Erich O Mikkelsen; Jens P Bagger; Claus H Gravholt
Journal:  J Physiol       Date:  2002-02-15       Impact factor: 5.182

4.  Development of longitudinal smooth muscle in the posterior mesenteric artery and purinergic regulation of its contractile responses in chickens.

Authors:  Takahiko Shiina; Masato Koga; Shouichiro Saito; Yasuro Atoji; Tadashi Takewaki; Yasutake Shimizu
Journal:  J Comp Physiol A Neuroethol Sens Neural Behav Physiol       Date:  2013-08-21       Impact factor: 1.836

Review 5.  Coronary remodeling and biomechanics: Are we going with the flow in 2020?

Authors:  Patricia E McCallinhart; Benjamin W Scandling; Aaron J Trask
Journal:  Am J Physiol Heart Circ Physiol       Date:  2020-11-13       Impact factor: 4.733

6.  Non-endothelial endothelin counteracts hypoxic vasodilation in porcine large coronary arteries.

Authors:  Elise R Hedegaard; Edgaras Stankevicius; Ulf Simonsen; Ole Fröbert
Journal:  BMC Physiol       Date:  2011-05-15
  6 in total