| Literature DB >> 10348130 |
K Ueyama1, H Ohashi, Y Tsutsumi, T Kawai, T Ueda, M Ohnaka.
Abstract
The patency of coronary artery bypass grafts was evaluated by helical computed tomographic (CT) scan. One hundred forty patients who received an enhanced chest CT scan and a coronary angiography after bypass surgery were studied before discharge at the Fukui Cardiovascular Center. Among them was a total of 398 grafts and 436 anastomoses. For the evaluation of 248 vein grafts, the CT scan showed a 99.5% correct positive ratio and an overall accuracy of 96.4%. In 122 internal thoracic arteries tested, an overall accuracy of 64.7% was obtained. In gastroepiploic artery tests the overall accuracy was 33.3% and in radial artery tests it was 45.5%. Thirty-seven venous sequential anastomoses in 34 grafts and 1 internal thoracic artery sequential anastomosis were also evaluated. In the venous sequential anastomosis, the CT scan showed a 73.0% of accuracy overall. This study showed that the helical CT scan was useful to evaluate graft patency following bypass surgery.Entities:
Mesh:
Year: 1999 PMID: 10348130 DOI: 10.1002/(SICI)1522-726X(199903)46:3<322::AID-CCD12>3.0.CO;2-E
Source DB: PubMed Journal: Catheter Cardiovasc Interv ISSN: 1522-1946 Impact factor: 2.692