Influence of flow rate on aerosol particle size distributions from pressurized and breath-actuated inhalers.

K J Smith1, H K Chan, K F Brown.   

Abstract

Particle size distribution of delivered aerosols and the total mass of drug delivered from the inhaler are important determinants of pulmonary deposition and response to inhalation therapy. Inhalation flow rate may vary between patients and from dose to dose. The Andersen Sampler (AS) cascade impactor operated at flow rates of 30 and 55 L/min and the Marple-Miller Impactor (MMI) operated at flow rates of 30, 55, and 80 L/min were used in this study to investigate the influence of airflow rate on the particle size distributions of inhalation products. Total mass of drug delivered from the inhaler, fine particle mass, fine particle fraction, percentage of nonrespirable particles, and amount of formulation retained within the inhaler were determined by ultraviolet spectrophotometry for several commercial bronchodilator products purchased in the marketplace, including a pressurized metered-dose inhaler (pMDI), breath-actuated pressurized inhaler (BAMDI), and three dry powder inhalers (DPIs), two containing salbutamol sulphate and the other containing terbutaline sulphate. Varying the flow rate through the cascade impactor produced no significant change in performance of the pressurized inhalers. Increasing the flow rate produced a greater mass of drug delivered and an increase in respirable particle mass and fraction from all DPIs tested.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10346666     DOI: 10.1089/jam.1998.11.231

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  8 in total

1.  Use of solid corrugated particles to enhance powder aerosol performance.

Authors:  N Y Chew; H K Chan
Journal:  Pharm Res       Date:  2001-11       Impact factor: 4.200

2.  Optical feedback training of inhalation with Autohaler and Turbuhaler in COPD patients.

Authors:  J Steier; T Trammer; R M Cloes; W Petro
Journal:  Lung       Date:  2003       Impact factor: 2.584

3.  Factors Determining In Vitro Lung Deposition of Albuterol Aerosol Delivered by Ventolin Metered-Dose Inhaler.

Authors:  Rajoshi Biswas; Nicola A Hanania; Ashutosh Sabharwal
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2017-02-03       Impact factor: 2.849

4.  Influence of particle size, air flow, and inhaler device on the dispersion of mannitol powders as aerosols.

Authors:  N Y Chew; H K Chan
Journal:  Pharm Res       Date:  1999-07       Impact factor: 4.200

5.  Generation of micro-particles of proteins for aerosol delivery using high pressure modified carbon dioxide.

Authors:  R T Bustami; H K Chan; F Dehghani; N R Foster
Journal:  Pharm Res       Date:  2000-11       Impact factor: 4.200

6.  Salbutamol pMDI gives less protection to methacholine induced airway obstruction than salbutamol via spacer or DPI.

Authors:  Mariëlle E A C Broeders; Johan Molema; Wim C J Hop; Hans Th M Folgering
Journal:  Eur J Clin Pharmacol       Date:  2004-12-30       Impact factor: 2.953

7.  The influence of flow rate on the aerosol deposition profile and electrostatic charge of single and combination metered dose inhalers.

Authors:  Susan Hoe; Daniela Traini; Hak-Kim Chan; Paul M Young
Journal:  Pharm Res       Date:  2009-10-06       Impact factor: 4.200

8.  Efficacy and safety of ipratropium bromide/salbutamol sulphate administered in a hydrofluoroalkane metered-dose inhaler for the treatment of COPD.

Authors:  Amal Bhattacharya; Salil Bhargava; Virendra Singh; Deepak Talwar; Jagdeep Whig; Juliet Rebello; Shrinivas Purandare; Jaideep Gogtay
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2016-06-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.