Temporomandibular joint pantomography using charge-coupled device, photostimulable phosphor, and film receptors: a comparison.

T T Farman1, A G Farman.   

Abstract

Our objective was to compare the accuracy and practicality in use of three available imaging receptors for temporomandibular joint (TMJ) imaging; namely, two computer-assisted and one traditional analog x-ray film system. A standardized tissue-equivalent encased human skull specimen was imaged using lateral and posteroanterior (PA) pantomographic projections with the Orthopantomograph OP 100 (Instrumentarium Imaging, Tuusula, Finland) and three different receptor modalities: (1) Ektavision film with Ektavision screens (Eastman Kodak, Rochester, NY); (2) DenOptix photostimulable phosphor screens (Dentsply/Gendex, Chicago, IL); and (3) the charge-coupled device (CCD) receptor, DigiPan (TREX/Trophy Radiology, Marne-la-Vallée, France). The effective focal trough was found for each receptor using lead resolution grids placed at fractional millimeter distances along empirically determined beam projection angulations. The time to acquire and process images was also established. We found that the CCD system permitted real-time display, whereas the use of traditional film took 2 minutes to load the cassette in a darkroom and perform the exposure, and then a further 2 minutes to unload and process. The storage phosphor took 3 minutes to unload the cassette and process the image and a further 20 seconds to clear the plate following laser scanning. Film produced the greatest maximum resolution followed by the storage phosphor and the CCD. In conclusion, CCD-based TMJ pantomography provided an instant image. The photostimulable phosphor system used was the least satisfactory in terms of the time expended to obtain an image, but provided better spatial resolution than the CCD. Ektavision film/screens provided the best spatial resolution in this investigation.

Entities:  

Mesh:

Year:  1999        PMID: 10342155      PMCID: PMC3452917          DOI: 10.1007/BF03168744

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  5 in total

1.  Charge-coupled device panoramic radiography: effect of beam energy on radiation exposure.

Authors:  T T Farman; A G Farman; M S Kelly; F J Firriolo; J M Yancey; A V Stewart
Journal:  Dentomaxillofac Radiol       Date:  1998-01       Impact factor: 2.419

2.  The OP 100 Digipan: evaluation of the image layer, magnification factors, and dosimetry.

Authors:  T T Farman; M S Kelly; A G Farman
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1997-02

3.  Correlation of temporomandibular dysfunction with radiographic findings.

Authors:  L A Weinberg
Journal:  J Prosthet Dent       Date:  1972-11       Impact factor: 3.426

Review 4.  Current trends in temporomandibular joint imaging.

Authors:  T A Larheim
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1995-11

5.  Radiology of the temporomandibular joint.

Authors:  A Berrett
Journal:  Dent Clin North Am       Date:  1983-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.