[Heart perforation following transvenous implantation of a cardiac pacemaker].

J A Trigano1, F Paganelli, P Ricard, A Ferracci, J F Avierinos, S Lévy.   

Abstract

OBJECTIVES: We studied the incidence, clinical signs and severity of heart perforations occurring after transvenous pacemaker implantation. PATIENTS AND METHODS: A series of 16 consecutive cases of heart perforation observed in one cardiac pacing unit from 1989 to 1998 were reviewed.
RESULTS: Heart perforation occurred after implantation in 9 cases; the verall incidence for all lead implantation was 0.57%. The ventricle was perforated in 6 cases, the atrium in 1, and an undetermined site in 2 cases. Active fixation was involved in 5 cases, passive fixation in 4. A bipolar lead was used in 7 cases and a unipolar lead in 2. Heart perforation occurred after prior external stimulation in 7 cases, including one case with tamponnade requiring emergency pericardial drainage after implantation. Repositioning the lead in the ventricle was sufficient in 6 cases and a thoracotomy for an atrial wound was performed in 1 case. Difficulties in right ventricular catheterism due to kyphoscoliosis in elderly subjects was found to be a risk factor.
CONCLUSION: Heart perforation following transvenous pacemaker implantation is an exceptional complication with currently used material. Tamponnade is extremely rare. Besides verifying the mechanical performance of the leads, prevention requires a rigorous protocol for catheterism and wall fixation.

Entities:  

Mesh:

Year:  1999        PMID: 10337335

Source DB:  PubMed          Journal:  Presse Med        ISSN: 0755-4982            Impact factor:   1.228


  3 in total

1.  Outcome of cardioverter-defibrillator implant in patients with arrhythmogenic right ventricular cardiomyopathy.

Authors:  Giuseppe Boriani; Paolo Artale; Mauro Biffi; Cristian Martignani; Lorenzo Frabetti; Cinzia Valzania; Igor Diemberger; Matteo Ziacchi; Matteo Bertini; Claudio Rapezzi; Mario Parlapiano; Angelo Branzi
Journal:  Heart Vessels       Date:  2007-05-21       Impact factor: 2.037

2.  Successful management of late right ventricular perforation after pacemaker implantation.

Authors:  Amir K Bigdeli; Andres Beiras-Fernandez; Ingo Kaczmarek; Christian Kowalski; Michael Schmoeckel; Bruno Reichart
Journal:  Vasc Health Risk Manag       Date:  2010-02-04

3.  Perforation of right ventricle with cardiac tamponade following pacemaker implantation.

Authors:  Luciano Santana-Cabrera; Guillermo Pérez-Acosta; Raquel Manzanedo-Velasco; Manuel Sánchez-Palacios
Journal:  Int J Crit Illn Inj Sci       Date:  2011-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.