Literature DB >> 10337287

Laboratory evaluation and clinical application of a new one-bottle adhesive.

J Perdigão1, L N Baratieri, M Lopes.   

Abstract

PURPOSE: The purposes of this project were to compare the enamel and dentin bond strengths of a new nanofilled one-coat adhesive system with its predecessor, an unfilled two-coat adhesive system; to analyze the dentin interfacial ultramorphology, using scanning and transmission electron microscopy (SEM and TEM); and to illustrate the clinical technique associated with the use of the new nanofilled one-coat adhesive system.
MATERIAL AND METHODS: Twenty flat dentin surfaces and 20 flat enamel surfaces were polished on the labial surface of bovine incisors mounted in acrylic resin. The specimens were equally and randomly assigned to four bonding groups: (1) dentin with Prime & Bond 2.1; (2) dentin with Prime & Bond NT; (3) enamel with Prime & Bond 2.1; and (4) enamel with Prime & Bond NT. A composite post was then adapted to the treated area and light-cured. After thermocycling, shear bond strengths were determined by testing the shear strength of the specimens. The data were analyzed using one-way analysis of variance (ANOVA) and Student's t-test. For SEM and TEM, six dentin disks were obtained from middle dentin of human third molars and assigned equally to each adhesive. The adhesives were applied to dentin according to manufacturer's directions. The hybrid layer and resin penetration into dentin tubules were analyzed at an ultramorphologic level, and the observations were compared.
RESULTS: Shear bond strengths were as follows: group 1: 17.8 +/- 4.1 MPa; group 2: 20.5 +/- 3.5 MPa; group 3: 24.7 +/- 6.7 MPa; and group 4; 27.0 +/- 5.4 MPa. Electron microscopy showed that both adhesives penetrated the dentin tubules and formed a fully infiltrated hybrid layer. The nanofiller included in the new one-application adhesive penetrated the dentin tubules and infiltrated the microspaces between the collagen fibers within the hybrid layer. CLINICAL SIGNIFICANCE: The new one-application nanofilled adhesive tested in this study resulted in bond strengths and dentin hybridization comparable to those obtained with the corresponding two-application system. The clinical sequences presented illustrate the ease of use of the newest simplified adhesives.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10337287     DOI: 10.1111/j.1708-8240.1999.tb00373.x

Source DB:  PubMed          Journal:  J Esthet Dent        ISSN: 1040-1466


  3 in total

1.  Shear bond strength of adhesive systems to enamel and dentin. Thermocycling influence.

Authors:  Patrícia Aleixo Dos Santos; Patrícia Petromilli Nordi Sasso Garcia; Regina Guenka Palma-Dibb
Journal:  J Mater Sci Mater Med       Date:  2005-08       Impact factor: 3.896

2.  Comparative evaluation of the bonding efficacy of sixth and seventh generation bonding agents: An In-Vitro study.

Authors:  Manuja Nair; Joseph Paul; Satheesh Kumar; Yadav Chakravarthy; Vel Krishna
Journal:  J Conserv Dent       Date:  2014-01

3.  Influence of filler existence on microleakage of a self-etch adhesive system.

Authors:  H Mirmohammadi; K Khosravi; K Kashani; Cj Kleverlaan; Aj Feilzer
Journal:  J Conserv Dent       Date:  2014-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.