Literature DB >> 10333683

Estimation of blood perfusion using ultrasound.

T Jansson1, H W Persson, K Lindström.   

Abstract

Ways to measure blood perfusion using ultrasound techniques such as continuous-wave Doppler, pulsed Doppler, colour Doppler and power Doppler will be reviewed. From a certain standpoint, blood perfusion may be defined as the difference between arterial inflow and arterial outflow from a considered volume, i.e. capillary flow. The low velocities and small blood volumes involved make the signal-to-noise ratio, dynamic range and frequency resolution critical factors in the detection system. Another limiting factor is tissue motion which obscures the blood signal. Perfusion may still under certain conditions be estimated with the first moment of the Doppler power spectrum, as obtained with any Doppler ultrasound method. Modern flow mapping techniques also make it possible to estimate perfusion by counting the number of pixels that indicate flow, but low flow velocities cannot be included in the estimate. Future high-frequency systems may, however, provide very detailed images of minute flow distributions in superficial layers. Contrast agents are widely used today to enhance the blood signal, and a technique named harmonic imaging can suppress movement artefacts from surrounding tissue. Transient signals from disrupting contrast agent particles in an ultrasound field can potentially be used for perfusion quantification. Future developments to extract the blood flow signal from its noisy environment, aside from contrast agents, may be multiple sample volumes, frequency compounding and/or improved signal processing. The lack of an adequate perfusion phantom for verification of measurements of microcirculatory flow becomes, however, more apparent with improved detectability of slow flows.

Mesh:

Substances:

Year:  1999        PMID: 10333683     DOI: 10.1243/0954411991534834

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  2 in total

Review 1.  [Vascular imaging with contrast-enhanced sonography for experimental use].

Authors:  M Krix; H-U Kauczor; S Delorme
Journal:  Radiologe       Date:  2005-06       Impact factor: 0.635

2.  Evaluation of antral follicle growth in the macaque ovary during the menstrual cycle and controlled ovarian stimulation by high-resolution ultrasonography.

Authors:  Cecily V Bishop; Michelle L Sparman; Jessica E Stanley; Alistair Bahar; Mary B Zelinski; Richard L Stouffer
Journal:  Am J Primatol       Date:  2009-05       Impact factor: 2.371

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.