Literature DB >> 10333414

Aortoduodenal fistula arising from the dilatation of a knitted Dacron graft: report of a case.

M Matsushita1, Y Asano, I Kobayashi, T Tamauchi.   

Abstract

A fatal aortoduodenal fistula occurred in a 72-year-old man who underwent a repair of an abdominal aortic aneurysm 16 years previously with a 20 x 10 mm bifurcated knitted Dacron graft. The aortic part of his bifurcated graft had dilated to 40 mm in diameter, with a discrepancy of 20 mm in the diameter between the graft and infrarenal aorta. The fourth portion of the duodenum adhered to the left side of the anastomosis, where the aortoenteric fistula had occurred. We believe that the graft dilatation was the cause of the anastomotic failure, although other factors such as atherosclerotic degeneration of the host aorta should also be considered. Knitted Dacron grafts that have been implanted for more than 10 years should therefore be monitored carefully because they have an inherent tendency to dilate, especially those manufactured before 1981.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10333414     DOI: 10.1007/BF02483035

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  12 in total

1.  Failure of Dacron prostheses caused by structural defect.

Authors:  J J Yashar; M H Richman; J Dyckman; M Witoszka; R J Burnard; A K Weyman; J Yashar
Journal:  Surgery       Date:  1978-11       Impact factor: 3.982

2.  Clinical significance of aortic graft dilation.

Authors:  R M Blumenberg; M L Gelfand; E A Barton; C A Bowers; D A Gittleman
Journal:  J Vasc Surg       Date:  1991-08       Impact factor: 4.268

3.  Failure of ultralightweight knitted Dacron grafts in arterial reconstruction.

Authors:  L W Ottinger; R C Darling; L S Wirthlin; R R Linton
Journal:  Arch Surg       Date:  1976-02

Review 4.  Late rupture of knitted velour Dacron arterial prostheses.

Authors:  H R Magee; C A Teague
Journal:  Aust N Z J Surg       Date:  1988-07

5.  Dilative characteristics of Microvel and Vasculour-II aortic bifurcation grafts.

Authors:  D B Nunn; M M Carter; M T Donohue; B Pourdeyhimi
Journal:  J Biomed Mater Res       Date:  1996-01

6.  Dilation of synthetic grafts and junctional aneurysms.

Authors:  A M Imparato; I Nathan; T S Riles
Journal:  Arch Surg       Date:  1979-11

7.  Failure of dacron arterial prostheses caused by structural defects.

Authors:  T Watanabe; A Kusaba; H Kuma; M Kina; K Okadome; K Inokuchi
Journal:  J Cardiovasc Surg (Torino)       Date:  1983 Mar-Apr       Impact factor: 1.888

8.  Late rupture of prosthetic aortic grafts. Presentation and management.

Authors:  J G Sladen; A N Gerein; R T Miyagishima
Journal:  Am J Surg       Date:  1987-05       Impact factor: 2.565

9.  Aneurysm of an arterial prosthesis. A case report.

Authors:  S Bak; E Gravgaard
Journal:  Acta Chir Scand       Date:  1986-12

10.  Dilation of knitted Dacron aortic prostheses and anastomotic false aneurysms: etiologic considerations.

Authors:  G P Clagett; J M Salander; W L Eddleman; S Cabellon; J R Youkey; D W Olson; J E Hutton; N M Rich
Journal:  Surgery       Date:  1983-01       Impact factor: 3.982

View more
  2 in total

1.  Secondary aortoduodenal fistula with a fatal outcome: report of six cases.

Authors:  Panagiotis Katsinelos; George Paroutoglou; Basilios Papaziogas; Athanasios Beltsis; Kostas Mimidis; Ioannis Pilpilidis; Panagiotis Tsolkas; Kostas Soufleris; Stergios Vradelis; Ioannis Koutelidakis
Journal:  Surg Today       Date:  2005       Impact factor: 2.549

2.  Clinical analysis of non-anastomotic aneurysms of implanted prosthetic grafts.

Authors:  Satoshi Yamamoto; Katsuyuki Hoshina; Hideo Kimura; Hiroyuki Okamoto; Kunihiro Shigematsu; Tetsuro Miyata; Toshiaki Watanabe
Journal:  Surg Today       Date:  2014-04-03       Impact factor: 2.549

  2 in total