Literature DB >> 10330557

Evaluation of a polyurethane jugular catheter in cats placed using a modified Seldinger technique.

G J Martin1, J S Rand.   

Abstract

OBJECTIVE: To describe and evaluate the placement of a new design of polyurethane jugular catheter in cats using a modification of the technique of Seldinger. The maintenance and use of these catheters for repeated blood sampling over several days in healthy and diabetic cats is reported. PROCEDURE: Thirty polyurethane jugular catheters were placed in 10 clinically healthy cats and 10 cats with diabetes mellitus using the modified Seldinger technique. Catheters were placed while the cats were under general anaesthesia.
RESULTS: The catheters remained in place for a range of 2 to 14 days (median 5 days) with no major complications. In all cats patency of the catheters was maintained until removal. All cats examined had patent jugular veins when assessed 4 or more weeks after the catheters were removed.
CONCLUSIONS: These polyurethane jugular catheters, when placed by a modified Seldinger technique, are effective and safe in cats, and jugular patency returns after the catheters are removed.