Literature DB >> 10328185

Reduced release of tissue factor by application of a centrifugal pump during cardiopulmonary bypass.

J Babin-Ebell1, M Misoph, W Müllges, K Neukam, O Elert.   

Abstract

The application of a centrifugal pump might lead to a reduced release of tissue factor (TF) due to less blood cell damage. This could result in a decrease in activation of the extrinsic pathway of coagulation and embolus formation. In the present study, 60 patients undergoing coronary artery bypass grafting were randomly assigned to a centrifugal or a roller pump. Plasma concentrations of TF, thrombin-antithrombin complex (TAT), and prothrombin fragments F1 + 2 were investigated before, during, and after cardiopulmonary bypass (CPB). Embolus detection was performed at the arterial line of CPB and transcranially by Doppler ultrasound. The centrifugal pump group revealed a lower TF release (area under the curve during CPB) when compared with the roller pump group [5661 (696-10359) vs 12681 (6383-17538) microg x min/l; median (lower - upper quartiles); P = 0.009]. In contrast, TAT and F1 + 2 formation did not differ between the groups, and neither did the total embolus count of both Doppler systems. Embolus counts did not correlate with TAT or F1 + 2 formation. In conclusion, the reduction in TF release by the application of a centrifugal pump seems to have little consequence on total thrombin formation. Since the applied Doppler systems seem to detect mainly microbubbles, conclusions regarding differences between the two pumps in the formation of thrombofibrinous clots cannot be drawn.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10328185     DOI: 10.1007/bf01747832

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  21 in total

1.  The effects of complement activation during cardiopulmonary bypass. Attenuation by hypothermia, heparin, and hemodilution.

Authors:  F D Moore; K G Warner; S Assousa; C R Valeri; S F Khuri
Journal:  Ann Surg       Date:  1988-07       Impact factor: 12.969

2.  Centrifugal and roller pumps--are there differences in coagulation and fibrinolysis during and after cardiopulmonary bypass?

Authors:  B E Steinbrueckner; U Steigerwald; F Keller; K Neukam; O Elert; J Babin-Ebell
Journal:  Heart Vessels       Date:  1995       Impact factor: 2.037

Review 3.  Basic identification criteria of Doppler microembolic signals. Consensus Committee of the Ninth International Cerebral Hemodynamic Symposium.

Authors: 
Journal:  Stroke       Date:  1995-06       Impact factor: 7.914

4.  Changes in coagulation and fibrinolytic parameters caused by extracorporeal circulation.

Authors:  R Grossmann; J Babin-Ebell; M Misoph; S Schwender; K Neukam; T Hickethier; O Elert; F Keller
Journal:  Heart Vessels       Date:  1996       Impact factor: 2.037

5.  Detection of circulating cerebral emboli using Doppler ultrasound in a sheep model.

Authors:  H Markus; A Loh; M M Brown
Journal:  J Neurol Sci       Date:  1994-03       Impact factor: 3.181

6.  Impairment of cerebral function following cardiac and other major surgery.

Authors:  T Treasure; P L Smith; S Newman; A Schneidau; P Joseph; P Ell; M J Harrison
Journal:  Eur J Cardiothorac Surg       Date:  1989       Impact factor: 4.191

Review 7.  Inflammatory mediators and their influence on haemostasis.

Authors:  A Salgado; J L Bóveda; J Monasterio; R M Segura; M Mourelle; J Gómez-Jiménez; R Peracaula
Journal:  Haemostasis       Date:  1994 Mar-Apr

8.  The effect of velocity on the appearance of embolic signals studied in transcranial Doppler models.

Authors:  D W Droste; H S Markus; D Nassiri; M M Brown
Journal:  Stroke       Date:  1994-05       Impact factor: 7.914

9.  Detection of asymptomatic cerebral embolic signals with Doppler ultrasound.

Authors:  H S Markus; D W Droste; M M Brown
Journal:  Lancet       Date:  1994-04-23       Impact factor: 79.321

10.  Reduced complement activation and improved postoperative performance after cardiopulmonary bypass with heparin-coated circuits.

Authors:  P G Jansen; H te Velthuis; R A Huybregts; R Paulus; E R Bulder; H I van der Spoel; P D Bezemer; E H Slaats; L Eijsman; C R Wildevuur
Journal:  J Thorac Cardiovasc Surg       Date:  1995-09       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.