Literature DB >> 10326722

Robustness of anatomically guided pixel-by-pixel algorithms for partial volume effect correction in positron emission tomography.

D Strul1, B Bendriem.   

Abstract

Several algorithms have been proposed to improve positron emission tomography quantification by combining anatomical and functional information in a pixel-by-pixel correction scheme. The precision of these methods when applied to real data depends on the precision of the manifold correction steps, such as full-width half-maximum modeling, magnetic resonance imaging-positron emission tomography registration, tissue segmentation, or background activity estimation. A good understanding of the influence of these parameters thus is critical to the effective use of the algorithms. In the current article, the authors present a monodimensional model that allows a simple theoretical and experimental evaluation of correction imprecision. The authors then assess correction robustness in three dimensions with computer simulations, and evaluate the validity of regional SD as a correction performance criterion.

Mesh:

Year:  1999        PMID: 10326722     DOI: 10.1097/00004647-199905000-00009

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  8 in total

1.  Implementation and application of a brain template for multiple volumes of interest.

Authors:  Alexander Hammers; Matthias J Koepp; Samantha L Free; Matthew Brett; Mark P Richardson; Claire Labbé; Vincent J Cunningham; David J Brooks; John Duncan
Journal:  Hum Brain Mapp       Date:  2002-03       Impact factor: 5.038

2.  Partial-volume effect correction in positron emission tomography brain scan image using super-resolution image reconstruction.

Authors:  T Meechai; S Tepmongkol; C Pluempitiwiriyawej
Journal:  Br J Radiol       Date:  2014-12-10       Impact factor: 3.039

3.  Correlation between gray matter density-adjusted brain perfusion and age using brain MR images of 202 healthy children.

Authors:  Yasuyuki Taki; Hiroshi Hashizume; Yuko Sassa; Hikaru Takeuchi; Kai Wu; Michiko Asano; Kohei Asano; Hiroshi Fukuda; Ryuta Kawashima
Journal:  Hum Brain Mapp       Date:  2011-01-21       Impact factor: 5.038

4.  AI-based applications in hybrid imaging: how to build smart and truly multi-parametric decision models for radiomics.

Authors:  Isabella Castiglioni; Francesca Gallivanone; Paolo Soda; Michele Avanzo; Joseph Stancanello; Marco Aiello; Matteo Interlenghi; Marco Salvatore
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-11       Impact factor: 9.236

Review 5.  PET/MRI for neurologic applications.

Authors:  Ciprian Catana; Alexander Drzezga; Wolf-Dieter Heiss; Bruce R Rosen
Journal:  J Nucl Med       Date:  2012-11-09       Impact factor: 10.057

6.  Pharmacokinetic Analysis of (64)Cu-ATSM Dynamic PET in Human Xenograft Tumors in Mice.

Authors:  Fan Li; Jesper Tranekjær Jørgensen; Jacob Madsen; Andreas Kjaer
Journal:  Diagnostics (Basel)       Date:  2015-03-27

7.  Iterative framework for image registration and partial volume correction in brain positron emission tomography.

Authors:  Keisuke Matsubara; Masanobu Ibaraki; Miho Shidahara; Toshibumi Kinoshita
Journal:  Radiol Phys Technol       Date:  2020-10-19

8.  A partial volume effect correction tailored for 18F-FDG-PET oncological studies.

Authors:  F Gallivanone; C Canevari; L Gianolli; C Salvatore; P A Della Rosa; M C Gilardi; I Castiglioni
Journal:  Biomed Res Int       Date:  2013-09-19       Impact factor: 3.411

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.