Literature DB >> 10320248

Quick, simple clamping technique in descending thoracic aortic aneurysm repair.

P Biglioli1, R Spirito, M Porqueddu, M Agrifoglio, G Pompilio, A Parolari, L Dainese, E Sisillo.   

Abstract

BACKGROUND: Although significant advances have been made in the surgical treatment of diseases affecting the descending thoracic aorta, paraplegia remains a devastating complication. We propose the quick, simple clamping technique to prevent spinal cord ischemic injury.
METHODS: From 1983 to 1998, 143 patients had descending thoracic aorta aneurysm repair. We divided the patients into the following three groups according to the surgical technique used: selective atriodistal bypass was used in group 1 (66 patients); simple clamping technique in group 2 (28 patients); and quick simple clamping technique in group 3 (49 patients). Mean aortic cross clamp time was 39+/-13 minutes in group 1, 37+/-11 minutes in group 2, and 17+/-6 minutes in group 3 (p<0.01 group 3 versus group 1 and group 2).
RESULTS: The overall incidence of paraplegia was 4.8% (7 patients), 4.5% (3 patients) in group 1, 14.3% (4 patients) in group 2, and 0 in group 3 (p<0.05 group 3 versus group 2). The overall in-hospital mortality rate was 5.5%. Multivariate logistic regression analysis showed a powerful effect of aortic cross-clamping time as risk factor for both paraplegia (p<0.008), with an odds ratio of 1.03 per minute, and in-hospital mortality (p<0.001), with an odds ratio of 2.5 per minute. The mean follow-up time was 65 months with a lower overall mortality rate in group 3 than in group 1 and group 2 (p<0.05).
CONCLUSION: In descending thoracic aortic aneurysm repair, spinal cord perfusion can be maintained adequately without reimplantation of segmental vessels or use of atriodistal bypass when the aortic cross-clamp time is short (<15 to 20 minutes).

Entities:  

Mesh:

Year:  1999        PMID: 10320248     DOI: 10.1016/s0003-4975(99)00146-0

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

1.  Intentional coverage of the left subclavian artery during endovascular stent graft repair for thoracic aortic disease.

Authors:  R Caronno; G Piffaretti; M Tozzi; C Lomazzi; N Rivolta; P Castelli
Journal:  Surg Endosc       Date:  2006-05-11       Impact factor: 4.584

Review 2.  Current strategies for spinal cord protection during thoracic and thoracoabdominal aortic aneurysm repair.

Authors:  Hideyuki Shimizu; Ryohei Yozu
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-03-30

3.  Endovascular repair of descending thoracic aortic aneurysm: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2005-11-01

4.  Midterm results of endovascular stent graft treatment for descending aortic aneurysms including high-risk patients.

Authors:  Roland H Wagner; Jörg Krenzien; Andreas Gussmann
Journal:  Ger Med Sci       Date:  2006-04-12

5.  Anomalies and variant anatomy of the aorta and the supra-aortic vessels: additional challenges met by hybrid procedures.

Authors:  F Setacci; P Sirignano; G de Donato; E Chisci; G Galzerano; C Setacci
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2009

6.  Surgical resection and survival of patients with unsuspected single node positive lung cancer (NSCLC) invading the descending aorta.

Authors:  Peter Wex; Thomas Graeter; Francesco Zaraca; Victor Haas; Steffen Decker; Hansanali Bugdayev; Heinrich Ebner
Journal:  Thorac Surg Sci       Date:  2009-07-14

7.  Complications after endovascular stent-grafting of thoracic aortic diseases.

Authors:  Gabriele Piffaretti; Matteo Tozzi; Chiara Lomazzi; Nicola Rivolta; Roberto Caronno; Patrizio Castelli
Journal:  J Cardiothorac Surg       Date:  2006-09-12       Impact factor: 1.637

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.