Literature DB >> 10319955

Radiologic and histopathologic evaluation of canine artery occlusion after collagen-coated platinum microcoil delivery.

S Tamatani1, T Ozawa, T Minakawa, S Takeuchi, T Koike, R Tanaka.   

Abstract

BACKGROUND AND
PURPOSE: Platinum coil embolization is one of the significant advances in interventional neuroradiologic techniques that has been introduced this decade. Our purpose was to evaluate the angiographic and histologic effects of collagen-coated platinum microcoil delivery in the canine artery.
METHODS: We embolized the bilateral internal maxillary arteries of 18 dogs; one uncoated and one collagen-primed coil was used in each dog. We evaluated all coils by angiography, macroscopy, and scanning electron microscopy within 30 minutes of embolization. We then studied a proportional number of coated and collagen-primed coils at either 1 or 3 days, or 1, 2, 3, 4, 8, 12, or 16 weeks postoperatively.
RESULTS: Six (33%) of 18 arteries embolized with uncoated coils were occluded 30 minutes after delivery, whereas 11 (61%) of 18 arteries treated with collagen-primed coils were occluded within 30 minutes of embolization. Late occlusion (3 weeks after embolization) occurred in 2 (25%) of 8 arteries embolized with untreated coils, and 6 (75%) of 8 arteries embolized with collagen-primed coils. We calculated differences in late occlusion rates by the chi2 (chi-square) test, and found these differences were significant (P=.04). Histologic findings of arteries embolized with unprimed coils revealed endothelial cell growth was limited to the organized thrombi 4 weeks after coil delivery. In contrast, endothelial cells grew directly on the collagen-primed coils 3 days postoperatively, and coils were completely covered by endothelial cells within 2 weeks. We found an organized thrombus in the inner space of coils in angiographically occluded arteries, a finding that was not evident in angiographically patent arteries.
CONCLUSION: Collagen-coated platinum coils can produce rapid and stable occlusion of embolized vessels.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10319955

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  13 in total

1.  In re: radiologic and histopathologic evaluation of canine artery occlusion after collagen-coated platinum microcoil delivery.

Authors:  G Guglielmi
Journal:  AJNR Am J Neuroradiol       Date:  2000-03       Impact factor: 3.825

2.  Mechanisms of endothelial cell attachment, proliferation, and differentiation on 4 types of platinum-based endovascular coils.

Authors:  Aditya S Pandey; James D San Antonio; Sankar Addya; Saul Surrey; Paolo Fortina; Elisabeth J Van Bockstaele; Erol Veznedaroglu
Journal:  World Neurosurg       Date:  2013-08-30       Impact factor: 2.104

3.  Cyanoacrylate embolization of experimental aneurysms.

Authors:  Jean Raymond; France Berthelet; Anne-Cécile Desfaits; Igor Salazkin; Daniel Roy
Journal:  AJNR Am J Neuroradiol       Date:  2002-01       Impact factor: 3.825

4.  Effects of endothelial injury on the rate of thrombus organization in canine carotid arteries occluded with microcoils.

Authors:  T Abruzzo; G G Shengelaia; M Workman; H J Cloft; D A Miller; J E Dion
Journal:  Interv Neuroradiol       Date:  2004-10-22       Impact factor: 1.610

5.  Histological evaluation of endothelial reactions after endovascular coil embolization for intracranial aneurysm. Clinical and experimental studies and review of the literature.

Authors:  T Ozawa; S Tamatani; T Koike; H Abe; Y Ito; Y Soga; H Hasegawa; K Morita; R Tanaka
Journal:  Interv Neuroradiol       Date:  2004-10-22       Impact factor: 1.610

6.  Delivery of human vascular endothelial growth factor with platinum coils enhances wall thickening and coil impregnation in a rat aneurysm model.

Authors:  J M Abrahams; M S Forman; M S Grady; S L Diamond
Journal:  AJNR Am J Neuroradiol       Date:  2001-08       Impact factor: 3.825

7.  Challenging the surgical rodent hindlimb ischemia model with the miniinterventional technique.

Authors:  Zhen W Zhuang; Jing Shi; John M Rhodes; Michael J Tsapakos; Michael Simons
Journal:  J Vasc Interv Radiol       Date:  2011-04-03       Impact factor: 3.464

8.  Interaction of vascular smooth muscle cells with collagen-impregnated embolization coils studied with a novel quantitative in vitro model.

Authors:  Todd Abruzzo; Harry J Cloft; Miroslav Marek; George G Shengelaia; Patrick B Snowhill; Sandra Miller Waldrop; Athanassios Sambanis
Journal:  AJNR Am J Neuroradiol       Date:  2002-04       Impact factor: 3.825

9.  Isolated progressive visual loss after coiling of paraclinoid aneurysms.

Authors:  G W Schmidt; S F Oster; K C Golnik; L M Tumialán; V Biousse; R Turbin; C J Prestigiacomo; N R Miller
Journal:  AJNR Am J Neuroradiol       Date:  2007 Nov-Dec       Impact factor: 3.825

10.  32P-oligodeoxynucleotide-coated coils to prevent arterial recanalization after embolization.

Authors:  Luc Levesque; Francis Gauthier; Jean Raymond; Guy Leclerc
Journal:  AJNR Am J Neuroradiol       Date:  2004 Jun-Jul       Impact factor: 3.825

View more