Literature DB >> 1024828

Bone imaging after total replacement arthroplasty of the hip joint. A follow-up with different radiopharmaceuticals.

H Creutzig.   

Abstract

Bone imaging was done in patients after total replacement arthroplasty of the hip joint every 3rd month using 99mTc-HEDP and 18F. Uptake ratios were estimated over cup/normal hip and femur prosthesis/normal thigh. Ratios decline rapidly and reach a stable level 6-9 months, postoperatively. Eight cases of late infection were predicted correctly 1-3 months before any radiologic evidence was present. In four cases there had been false-positive results with 99mTc-HEDP while 18F gave always correct information except in cases of soft tissue inflammation. Here both 99mTc-HEDP and 18F ratios were elevated. The early diagnosis of late complications after replacement arthroplasty seems to be possible. The clinical significance, however, is low: only one out of eight patients with manifest infection is still on conservative treatment. Bone imaging should be done to exclude late infection as a cause of pain after total replacement arthroplasty of the hip joint only.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1024828     DOI: 10.1007/BF00257968

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  11 in total

1.  [A comparison of osteotropic radiopharmaceuticals. II. Plasma clearance of 18F and 99mTc-EHDP (author's transl)].

Authors:  H Creutzig
Journal:  Rofo       Date:  1975-10

2.  [Bone scanning with 99m-Tc-polyphosphate and strontium isotopes (author's transl)].

Authors:  H Creutzig; H Hundeshagen
Journal:  Fortschr Geb Rontgenstr Nuklearmed       Date:  1973-11

3.  [Scintigraphic progress observations before and after alloplastic hip joint prosthesis].

Authors:  H Venohr; W Groher; H Klems
Journal:  Fortschr Geb Rontgenstr Nuklearmed       Date:  1972-09

4.  [Nuclear medicine findings on loosened and inflammed total endophrostheses].

Authors:  R Heep; H Lichte
Journal:  Hefte Unfallheilkd       Date:  1974

5.  [Scintigraphic findings in Bechterew's disease (author's transl)].

Authors:  H Venohr; H Klems
Journal:  Rontgenblatter       Date:  1974-10

6.  Bone-seeking radionuclides: an in vivo study of factors affecting skeletal uptake.

Authors:  H K Genant; G J Bautovich; M Singh; K A Lathrop; P V Harper
Journal:  Radiology       Date:  1974-11       Impact factor: 11.105

7.  85Sr radionuclide scintimetry in infected total hip arthroplasty.

Authors:  G C Bauer; L Lindberg; Y Naversten; L O Sjöstrand
Journal:  Acta Orthop Scand       Date:  1973

8.  The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.

Authors:  J Charnley
Journal:  J Bone Joint Surg Br       Date:  1972-02

9.  18F and 85Sr scintimetry in the study of primary arthropathies.

Authors:  G Muheim; W P Crutchlow
Journal:  Br J Radiol       Date:  1971-04       Impact factor: 3.039

10.  Radiology of total hip arthroplasty.

Authors:  J W Beabout
Journal:  Radiol Clin North Am       Date:  1975-04       Impact factor: 2.303

View more
  3 in total

1.  Visual Pattern and Serial Quantitation of 18F-Sodium Fluoride PET/CT in Asymptomatic Patients After Hip and Knee Arthroplasty.

Authors:  Hye Joo Son; Young Jin Jeong; Hyun Jin Yoon; Lih Wang; Hyeon Jun Kim; Jong-Hwan Park; Do-Young Kang
Journal:  Nucl Med Mol Imaging       Date:  2016-07-13

Review 2.  Investigation of joint disease.

Authors:  M V Merrick
Journal:  Eur J Nucl Med       Date:  1992

Review 3.  Review of the role of dynamic 18F-NaF PET in diagnosing and distinguishing between septic and aseptic loosening in hip prosthesis.

Authors:  Olu Adesanya; Andrew Sprowson; James Masters; Charles Hutchinson
Journal:  J Orthop Surg Res       Date:  2015-01-16       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.