Literature DB >> 10235089

Differences in TIMI frame count following successful reperfusion with stenting or percutaneous transluminal coronary angioplasty for acute myocardial infarction.

M E Edep1, E M Guarneri, P S Teirstein, P S Phillips, D L Brown.   

Abstract

The Thrombolysis In Myocardial Infarction (TIMI) flow grade achieved in the infarct-related artery (IRA) during reperfusion therapy for acute myocardial infarction (AMI) is directly related to myocardial salvage. Recently, several series have demonstrated the safety of stenting in AMI and documented a larger postprocedure luminal diameter than that found at angioplasty, although no study has compared the effect of PTCA and stenting in AMI on flow characteristics of the IRA. The residual stenosis and the number of frames required to opacify standardized angiographic landmarks normalized for vessel length (corrected TIMI frame count) or compared with flow in a corresponding normal coronary artery (TIMI frame count index) were determined for the IRA of 39 patients who underwent angioplasty or stenting for AMI. Baseline characteristics were similar for the 20 patients who underwent stenting and the 19 patients who underwent percutaneous transluminal coronary angioplasty. After intervention, the luminal diameter was greater (3.24 vs 2.09 mm, p <0.0001) and the residual stenosis was less (-9.4% vs. 26.7%, p <0.0001) after stenting than after percutaneous transluminal coronary angioplasty. These changes in vessel geometry were associated with a lower corrected TIMI frame count (16.1 vs 30.7, p <0.002) and a lower TIMI frame count index (0.68 vs 1.3, p <0.002). Thus, stenting in AMI is associated with a greater postprocedure luminal diameter and improvement in coronary blood flow as measured by the TIMI frame count method.

Entities:  

Mesh:

Year:  1999        PMID: 10235089     DOI: 10.1016/s0002-9149(99)00094-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Current Assessments of the Adequacy of Myocardial Perfusion During Acute MI.

Authors:  Allen Chang; C Michael Gibson
Journal:  Curr Treat Options Cardiovasc Med       Date:  2005-05

Review 2.  Use of the TIMI frame count in the assessment of coronary artery blood flow and microvascular function over the past 15 years.

Authors:  Vijayalakshmi Kunadian; Caitlin Harrigan; Cafer Zorkun; Alexandra M Palmer; Katherine J Ogando; Leah H Biller; Erin E Lord; Scott P Williams; Michelle E Lew; Lauren N Ciaglo; Jacqueline L Buros; Susan J Marble; William J Gibson; C Michael Gibson
Journal:  J Thromb Thrombolysis       Date:  2008-04-20       Impact factor: 2.300

3.  Importance of the TIMI frame count: implications for future trials.

Authors:  Mark A Appleby; Andrew D Michaels; Michael Chen; C Gibson Michael
Journal:  Curr Control Trials Cardiovasc Med       Date:  2000

4.  Does primary stenting preserve cardiac function in myocardial infarction? A case-control study. NORTH-981 investigators. Network of revascularisation therapy in Hokkaido.

Authors:  H Sasao; K Tsuchihashi; M Hase; T Nakata; K Shimamoto
Journal:  Heart       Date:  2000-11       Impact factor: 5.994

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.